Title: Hemodynamic Changes on Cone-Beam Computed Tomography during Balloon-Occluded Transcatheter Arterial Chemoembolization Using Miriplatin for Hepatocellular Carcinoma: A Preliminary Study. Author: Ishikawa T, Imai M, Owaki T, Sato H, Nozawa Y, Sano T, Iwanaga A, Seki K, Honma T, Yoshida T, Kudo M. Journal: Dig Dis; 2017; 35(6):598-601. PubMed ID: 29040993. Abstract: BACKGROUND/AIM: Balloon-occluded transcatheter arterial chemoembolization (B-TACE) using miriplatin (MPT) is anticipated as a new strategy for hepatocellular carcinoma (HCC). This study was aimed at evaluating the hemodynamic changes with/without balloon occlusion of the hepatic artery, correlation of cone-beam CT (CBCT) pixels, and CT value after B-TACE for HCC. METHODS: A total of 52 patients with HCC, who underwent B-TACE using MPT in addition to the balloon-occluded CBCT hepatic arteriography, were studied. RESULTS: After balloon occlusion, CBCT pixel values increased in 37 lesions, whereas it decreased in 15 lesions. Intratumoral CT values after B-TACE were lower with decreased CBCT pixel values than with increased CBCT pixel values. CONCLUSION: Hemodynamic changes on CBCT during balloon occlusion can be used to predict the efficacy of B-TACE using MPT.[Abstract] [Full Text] [Related] [New Search]