These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Hemodynamic Changes on Cone-Beam Computed Tomography during Balloon-Occluded Transcatheter Arterial Chemoembolization Using Miriplatin for Hepatocellular Carcinoma: A Preliminary Study.
    Author: Ishikawa T, Imai M, Owaki T, Sato H, Nozawa Y, Sano T, Iwanaga A, Seki K, Honma T, Yoshida T, Kudo M.
    Journal: Dig Dis; 2017; 35(6):598-601. PubMed ID: 29040993.
    Abstract:
    BACKGROUND/AIM: Balloon-occluded transcatheter arterial chemoembolization (B-TACE) using miriplatin (MPT) is anticipated as a new strategy for hepatocellular carcinoma (HCC). This study was aimed at evaluating the hemodynamic changes with/without balloon occlusion of the hepatic artery, correlation of cone-beam CT (CBCT) pixels, and CT value after B-TACE for HCC. METHODS: A total of 52 patients with HCC, who underwent B-TACE using MPT in addition to the balloon-occluded CBCT hepatic arteriography, were studied. RESULTS: After balloon occlusion, CBCT pixel values increased in 37 lesions, whereas it decreased in 15 lesions. Intratumoral CT values after B-TACE were lower with decreased CBCT pixel values than with increased CBCT pixel values. CONCLUSION: Hemodynamic changes on CBCT during balloon occlusion can be used to predict the efficacy of B-TACE using MPT.
    [Abstract] [Full Text] [Related] [New Search]