These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Bioprosthesis leaflet thrombosis following self-expanding valve-in-valve transcatheter aortic valve replacement in patient taking factor Xa inhibitor and warfarin: A case report.
    Author: Buchanan KD, Alraies MC, Weissman G, Ben-Dor I, Satler LF, Waksman R.
    Journal: Cardiovasc Revasc Med; 2018 Jan; 19(1 Pt A):29-32. PubMed ID: 29066342.
    Abstract:
    An 87-year-old female with symptomatic severe aortic stenosis underwent transcatheter valve replacement (TAVR) via the transfemoral approach with a 29mm self-expanding device. Moderate to severe paravalvular regurgitation led to the development of congestive heart failure and hospital readmission 1 month following TAVR. A second 29mm valve was placed to abolish the paravalvular regurgitation. Routine follow-up computed tomography (CT) imaging demonstrated leaflet thickening and decreased leaflet mobility suggesting valve thrombosis, despite adherence to Factor Xa inhibitor. Transthoracic echocardiogram revealed normal transaortic valve gradients. The patient was transitioned to a vitamin K antagonist and repeat imaging 3months later demonstrated progression of thrombosis to an additional leaflet. The case illustrates the potential increased risk of leaflet thrombosis in patients receiving valve-in-valve TAVR procedures, the superiority of multidetector computed tomography to image subclinical leaflet thrombosis, and highlights the need for further investigation in this area.
    [Abstract] [Full Text] [Related] [New Search]