These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Magnetic Resonance Imaging Grading System for Preoperative Diagnosis of Leiomyomas and Uterine Smooth Muscle Tumors.
    Author: Suzuki Y, Wada S, Nakajima A, Fukushi Y, Hayashi M, Matsuda T, Asano R, Sakurai Y, Noguchi H, Shinohara T, Sato C, Fujino T.
    Journal: J Minim Invasive Gynecol; 2018; 25(3):507-513. PubMed ID: 29079462.
    Abstract:
    STUDY OBJECTIVE: To evaluate a new magnetic resonance imaging (MRI) grading system for preoperative differentiation between benign and variant-type uterine leiomyomas including smooth muscle tumors of uncertain malignant potential (STUMPs). DESIGN: Retrospective analysis (Canadian Task Force classification III). SETTING: Teaching hospital (Teine Keijinkai Hospital). PATIENTS: Three-hundred thirteen patient medical records were retrospectively reviewed if treated for uterine myomas and diagnosed with variant type leiomyomas or STUMPs (n = 27) or benign, typical leiomyomas (n = 286) and treated between January 2012 and December 2014. INTERVENTION: Uterine myoma classifications using MRI findings according to a 5-grade system (grades I-V) based on 3 elements. MEASUREMENTS AND MAIN RESULTS: Uterine myoma MRI classifications were based on 3 elements: T2-weighted imaging (high or low), diffusion-weighted imaging (high or low), and apparent diffusion coefficient values (high or low; apparent diffusion coefficient < 1.5 × 10-3 mm2/sec was considered low). Grades I to II were designated as typical or benign leiomyomas, grade III as degenerated leiomyomas, and grades IV to V as variant type leiomyomas or STUMPs. Accuracy levels were 98.9%, 100%, 94.3%, 58.8%, and 41.9% for grades I through V lesions, respectively. The grades were divided into 2 groups to discriminate benign leiomyomas and STUMPs (grades I-III were considered negative and grades IV-V positive). Grades IV to V scored 85.2% for sensitivity, 91.3% for specificity, 47.9% positive predictive value, 98.5% negative predictive value, a 9.745 positive likelihood ratio, and a .162 negative likelihood ratio. CONCLUSION: This novel MRI grading system for uterine myomas may be beneficial in differentiating benign leiomyomas from STUMPs or variant type leiomyomas and could be a future effective presurgical assessment tool.
    [Abstract] [Full Text] [Related] [New Search]