These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Electrocardiographic-Guided Technique for Placement of Ventriculoatrial Shunts: A Valid and Cost-Effective Technical Simplification. Author: Della Pepa GM, Sabatino G, Peppucci E, Sturiale CL, Albanese A, Puca A, Olivi A, Marchese E, Perotti V. Journal: World Neurosurg; 2018 Jan; 109():455-459. PubMed ID: 29097337. Abstract: BACKGROUND: Ventriculoatrial (VA) shunt is a routine technique for the treatment of hydrocephalus. The correct position at the superior vena cava-right atrium junction is generally assessed by radiography. We present the first experience of an alternative, nonradiographic technique to assess the distal end of the VA shunts through an electrocardiographic (EKG) method. The technique has developed from the large experience of central venous catheters (CVC) worldwide; the EKG-guided method is a common and validated alternative to standard radiologic control of the location of the tip of any CVC. METHODS: Five consecutive patients underwent VA shunt with venous catheter positioned with the EKG-guided technique. The position of the catheter tip was verified by standard chest radiography. RESULTS: Four men and 1 woman (mean age, 45.4 years) underwent VA shunt for hydrocephalus with the EKG-guided technique. The side of internal jugular vein puncture was the right side in 4 cases and the left side in 1 case. As confirmed by radiography, all VA shunt tips were located within the correct range. There was no radiologic evidence of procedure-related complication or catheters that had to be replaced. CONCLUSIONS: The EKG-guided technique for VA shunts is as accurate as fluoroscopy, but simpler, more readily available, less expensive, safer, and more cost effective. It reduces the need of radiography and radiologic exposition for both patients and operators. The EKG method may be a valid and cost-effective alternative to standard radiologic control in VA shunts, as for any central venous access device, and could become the preferential method for confirming tip position during VA shunt surgery.[Abstract] [Full Text] [Related] [New Search]