These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The Role of Holter Monitoring in the Diagnosis of Early Repolarisation Pattern.
    Author: Ji CC, Chen XM, Cheng YJ, Liu LJ, Tang K, Zhu WQ, Huang Y, Chen WY, Wu SH.
    Journal: Heart Lung Circ; 2018 Dec; 27(12):1421-1427. PubMed ID: 29129560.
    Abstract:
    BACKGROUND: A slower heart rate can exaggerate J-point elevation in a 12-lead ECG. This study examined the role of Holter monitoring in the diagnosis of early repolarisation pattern (ERP). METHODS: We examined 24-hour Holter recordings of 4000 consecutive patients seen at an outpatient clinic, and found 500 patients (12.5%) with ERP (based on J-point elevation magnitude maximum value≥0.1mV on the Holter recording). The highest magnitude of J-point elevation, R wave amplitude, the ratio between J-point elevation magnitude and R-wave amplitude on the same ECG lead (J/R ratio), QRS interval, and QT/QTc interval were measured on the Holter recording and on a surface 12-lead ECG of the 500 patients with ERP. The magnitude of J-point elevation, J/R ratio, and QT/QTc interval were compared between three groups: nighttime Holter recording, daytime Holter recording, and daytime surface 12-lead ECG. RESULTS: The magnitude of J-point elevation of the nighttime Holter (0.20±0.10mV) was higher than that of the daytime in Holter (0.12±0.07mV, p<0.001) and the 12-lead ECG (0.12±0.06mV, p<0.001). There was no statistical difference in magnitude of J-point elevation between daytime Holter and surface 12-lead ECG. While all 500 patients were diagnosed with ERP based on J-point elevation maximum value J-point on Holter monitoring, only 425 (85%) patients could be diagnosed with ERP based on the surface 12-lead ECG. The J-point elevation maximum value on the nighttime Holter was negatively correlated with heart rate (r=-0.15, p=0.0007) and QTc (r=-0.13, p=0.0043), and positively correlated with R wave amplitude (r=0.46, p<0.0001), J/R ratio (r=0.69, p<0.0001), and QRS interval (r=0.29, p<0.0001). CONCLUSIONS: The J-point elevation on nighttime Holter recording was higher than that on daytime Holter and daytime surface 12-lead ECG, and there was misdiagnosis of ERP based on daytime surface 12-lead ECG. Holter monitoring has a complementary role in the diagnosis of ERP, especially in patients with a suspected diagnosis of ERP based on daytime surface 12-lead ECG.
    [Abstract] [Full Text] [Related] [New Search]