These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Validation of T1w-based segmentations of white matter hyperintensity volumes in large-scale datasets of aging. Author: Dadar M, Maranzano J, Ducharme S, Carmichael OT, Decarli C, Collins DL, Alzheimer's Disease Neuroimaging Initiative. Journal: Hum Brain Mapp; 2018 Mar; 39(3):1093-1107. PubMed ID: 29181872. Abstract: INTRODUCTION: Fluid-attenuated Inversion Recovery (FLAIR) and dual T2w and proton density (PD) magnetic resonance images (MRIs) are considered to be the optimum sequences for detecting white matter hyperintensities (WMHs) in aging and Alzheimer's disease populations. However, many existing large multisite studies forgo their acquisition in favor of other MRI sequences due to economic and time constraints. METHODS: In this article, we have investigated whether FLAIR and T2w/PD sequences are necessary to detect WMHs in Alzheimer's and aging studies, compared to using only T1w images. Using a previously validated automated tool based on a Random Forests classifier, WMHs were segmented for the baseline visits of subjects from ADC, ADNI1, and ADNI2/GO studies with and without T2w/PD and FLAIR information. The obtained WMH loads (WMHLs) in different lobes were then correlated with manually segmented WMHLs, each other, age, cognitive, and clinical measures to assess the strength of the correlations with and without using T2w/PD and FLAIR information. RESULTS: The WMHLs obtained from T1w-Only segmentations correlated with the manual WMHLs (ADNI1: r = .743, p < .001, ADNI2/GO: r = .904, p < .001), segmentations obtained from T1w + T2w + PD for ADNI1 (r = .888, p < .001) and T1w + FLAIR for ADNI2/GO (r = .969, p < .001), age (ADNI1: r = .391, p < .001, ADNI2/GO: r = .466, p < .001), and ADAS13 (ADNI1: r = .227, p < .001, ADNI2/GO: r = .190, p < 0.001), and NPI (ADNI1: r = .290, p < .001, ADNI2/GO: r = 0.144, p < .001), controlling for age. CONCLUSION: Our results suggest that while T2w/PD and FLAIR provide more accurate estimates of the true WMHLs, T1w-Only segmentations can still provide estimates that hold strong correlations with the actual WMHLs, age, and performance on various cognitive/clinical scales, giving added value to datasets where T2w/PD or FLAIR are not available.[Abstract] [Full Text] [Related] [New Search]