Title: Improvement of the repeatability of parallel transmission at 7T using interleaved acquisition in the calibration scan. Author: Kameda H, Kudo K, Matsuda T, Harada T, Iwadate Y, Uwano I, Yamashita F, Yoshioka K, Sasaki M, Shirato H. Journal: J Magn Reson Imaging; 2018 Jul; 48(1):94-101. PubMed ID: 29205623. Abstract: BACKGROUND: Respiration-induced phase shift affects B0 /B1+ mapping repeatability in parallel transmission (pTx) calibration for 7T brain MRI, but is improved by breath-holding (BH). However, BH cannot be applied during long scans. PURPOSE: To examine whether interleaved acquisition during calibration scanning could improve pTx repeatability and image homogeneity. STUDY TYPE: Prospective. SUBJECTS: Nine healthy subjects. FIELD STRENGTH/SEQUENCE: 7T MRI with a two-channel RF transmission system was used. ASSESSMENT: Calibration scanning for B0 /B1+ mapping was performed under sequential acquisition/free-breathing (Seq-FB), Seq-BH, and interleaved acquisition/FB (Int-FB) conditions. The B0 map was calculated with two echo times, and the B1+ map was obtained using the Bloch-Siegert method. Actual flip-angle imaging (AFI) and gradient echo (GRE) imaging were performed using pTx and quadrature-Tx (qTx). All scans were acquired in five sessions. Repeatability was evaluated using intersession standard deviation (SD) or coefficient of variance (CV), and in-plane homogeneity was evaluated using in-plane CV. STATISTICAL TESTS: A paired t-test with Bonferroni correction for multiple comparisons was used. RESULTS: The intersession CV/SDs for the B0 /B1+ maps were significantly smaller in Int-FB than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The intersession CVs for the AFI and GRE images were also significantly smaller in Int-FB, Seq-BH, and qTx than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The in-plane CVs for the AFI and GRE images in Seq-FB, Int-FB, and Seq-BH were significantly smaller than in qTx (Bonferroni-corrected P < 0.01 for all). DATA CONCLUSION: Using interleaved acquisition during calibration scans of pTx for 7T brain MRI improved the repeatability of B0 /B1+ mapping, AFI, and GRE images, without BH. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.[Abstract] [Full Text] [Related] [New Search]