These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses. Author: Yilmaz B, Alp G, Seidt J, Johnston WM, Vitter R, McGlumphy EA. Journal: J Prosthet Dent; 2018 Jul; 120(1):79-84. PubMed ID: 29310879. Abstract: STATEMENT OF PROBLEM: The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. PURPOSE: The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. MATERIAL AND METHODS: Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). RESULTS: Statistically significant differences were found among load-to-fracture values of different HDPs (P<.001). GD and Po materials had significantly higher load-to-fracture values than other materials (P<.001), and no statistically significant differences were found between GD and Po. The lowest load-to-fracture values were observed for autopolymerized and BG materials, which were significantly lower than those of GD, Po, AE, AP, Z, MAT, Inj, and BS. The load-to-fracture value of autopolymerized acrylic resin was not significantly different from that of BG CAD-CAM polymer. CONCLUSIONS: GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers and injection-molded acrylic resin had similar load-to-fracture values, which were higher than those of BG and autopolymerized acrylic resin. Autopolymerized acrylic resin load-to-fracture value was similar to that of BG CAD-CAM polymer, which is colored in a gradient pattern.[Abstract] [Full Text] [Related] [New Search]