These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Vitreoretinal Complications and Outcomes in 92 Eyes Undergoing Surgery for Modified Osteo-Odonto-Keratoprosthesis: A 10-Year Review. Author: Rishi P, Rishi E, Agarwal V, Nair S, Iyer G, Srinivasan B, Agarwal S. Journal: Ophthalmology; 2018 Jun; 125(6):832-841. PubMed ID: 29342438. Abstract: PURPOSE: To analyze vitreoretinal (VR) complications and treatment outcomes in eyes undergoing modified osteo-odonto-keratoprosthesis (OOKP) surgery. DESIGN: Retrospective case series. PARTICIPANTS: All patients who underwent modified OOKP (mOOKP) surgery at a tertiary eye-care center from March 2003 to February 2013 were included. METHODS: Medical records were reviewed for relevant medical history, best-corrected visual acuity (BCVA), slit-lamp examination, ultrasound scan, oral examination findings, and VR complications. MAIN OUTCOME MEASURES: The BCVA at the last visit. Optimal anatomic outcome was attached retina with a normal intraocular pressure at the last visit. RESULTS: A total of 92 eyes of 90 patients were included. Indications for OOKP included Stevens-Johnson syndrome (n = 53), chemical injury (n = 36), and ocular cicatricial pemphigoid (n = 3). A total of 41 eyes of 39 patients developed VR complications, including vitritis (n = 21), retinal detachment (RD) (n = 12; primary RD = 5), retroprosthetic membrane (RPM) (n = 10; primary RPM = 2), endophthalmitis (n = 8), vitreous hemorrhage (VH) (n = 5; primary VH = 1), serous choroidal detachment (n = 5), hemorrhagic choroidal detachment (n = 2), and leak-related hypotony (n = 1). Mean interval from mOOKP surgery to occurrence of VR complication(s) was 43.8 months (median, 41.9 months; range, 0.2-95.5 months). After treatment of VR complication, visual improvement was seen in 17 eyes (42%) (mean improvement = 1.2 logarithm of the minimum angle of resolution [logMAR]; median, 0.8 logMAR; range, 0.1-2.5 logMAR), visual decline in 7 eyes (14%) (mean decline in BCVA = 0.6 logMAR; median, 0.4 logMAR; range, 0.3-1.8 logMAR), and no change in BCVA in 17 eyes (42%). However, BCVA ≥6/60 was retained in 19 eyes and ≥6/18 was retained in 9 eyes after final VR treatment. CONCLUSIONS: Vitreoretinal complications constitute a significant cause of visual morbidity in eyes undergoing mOOKP surgery and pose a challenging situation to manage. However, appropriate and timely intervention can achieve encouraging results.[Abstract] [Full Text] [Related] [New Search]