These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A rapid, LC-MS/MS assay for quantification of piperacillin and tazobactam in human plasma and pleural fluid; application to a clinical pharmacokinetic study.
    Author: Popowicz ND, O'Halloran SJ, Fitzgerald D, Lee YCG, Joyce DA.
    Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Apr 01; 1081-1082():58-66. PubMed ID: 29505960.
    Abstract:
    Piperacillin, in combination with tazobactam is a common first-line antibiotic used for the treatment of pleural infection, however its pleural pharmacokinetics and penetration has not previously been reported. The objective of this work was to develop and validate a rapid and sensitive liquid chromatography with tandem mass spectrometry (LC-MS/MS) assay for quantification of piperacillin (PIP) and tazobactam (TAZ). PIP and TAZ were extracted from both human plasma and pleural fluid samples by protein precipitation in methanol containing the internal standards (IS) piperacillin-d5 (PIP-d5) and sulbactam (SUL). Briefly, 5 μL of sample was mixed with 125 μL of methanol containing IS, vortexed and centrifuged. Supernatant (50 μL) was diluted into 500 μL of mobile phase containing 10 mM of ammonium bicarbonate in LCMS grade water and transferred to the autosampler tray. Electrospray ionization in positive mode and multiple reaction monitoring (MRM) were used for PIP and PIP-d5 at the transitions m/z 518.2 → 143.2 and m/z 523.2 → 148.2 respectively, and electrospray ionization in negative mode and MRM were used for TAZ and SUL at the transitions m/z 299.1 → 138.1 and m/z 232.4 → 140.1. The chromatographic separation was achieved using an Acquity BEH C-18 column with gradient elution of mobile phase containing 10 mmol/L ammonium bicarbonate in water and methanol. A linear range was observed over the concentration range of 0.25-352 mg/L and 0.25-50.5 mg/L for PIP and TAZ respectively. Complete method validation was performed according to US FDA guidelines for selectivity, specificity, precision and accuracy, LLOQ, matrix effects, recovery and stability, with all results within acceptable limits. This method was successfully applied to two patients with pleural infection and is suitable for further pharmacokinetic studies and therapeutic drug monitoring.
    [Abstract] [Full Text] [Related] [New Search]