These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Droplet digital PCR as a novel detection method for quantifying microRNAs in acute myocardial infarction. Author: Robinson S, Follo M, Haenel D, Mauler M, Stallmann D, Tewari M, Duerschmied D, Peter K, Bode C, Ahrens I, Hortmann M. Journal: Int J Cardiol; 2018 Apr 15; 257():247-254. PubMed ID: 29506703. Abstract: BACKGROUND: micro-RNAs have shown promise as potential biomarkers for acute myocardial infarction and ischemia-reperfusion injury (I/R). Most recently droplet digital polymerase chain reaction (ddPCR) has been introduced as a more reliable and reproducible method for detecting micro-RNAs. AIMS: We aimed to demonstrate the improved technical performance and diagnostic potential of ddPCR by measuring micro-RNAs in ST-elevation myocardial infarction (STEMI). METHODS: A dilution series was performed in duplicate on synthetic Caenorrhabditis elegans-miR-39, comparing quantitative real-time PCR (qRT-PCR) and ddPCR. We used ddPCR and qRT-PCR to quantify the serum levels of miR-21, miR-208a and miR-499 between STEMI patients (n=24) and stable coronary artery disease (CAD) patients (n=20). In STEMI, I/R injury was assessed via measurement of ST-segment resolution. RESULTS: In the dilution series, ddPCR demonstrated superior coefficient of variation (12.1%vs.32.9%) and limit of detection (0.9325 vs.2.425copies/μl). In the patient cohort, ddPCR demonstrated greater differences in miR-21 levels (2190.5 vs. 484.7copies/μl; p=0.0004 for ddPCR and 136.4 vs. 122.8copies/μl; p=0.2273 for qRT-PCR) and in miR-208a (0 vs. 24.1copies/μl, p=0.0013 for ddPCR and 0 vs. 0copies/μl, p=0.0032 for qRT-PCR), with similar differences observed in miR-499 levels (9.4 vs. 81.5copies/μl, p<0.0001 for ddPCR and 0 vs. 19.41copies/μl, p<0.0001 for qRT-PCR). ddPCR also more accurately defined STEMI for all miRNAs (area under the curve (AUC) of 0.8021/0.7740/0.9063 for miR-21/208a/499 with ddPCR vs. AUC of 0.6083/0.6917/0.8417 with qRT-PCR). However, there was no association between miR-21/208a/499 levels and ischemia-reperfusion injury. CONCLUSION: ddPCR demonstrates superiority in both technical performance and diagnostic potential compared to qRT-PCR. Ultimately, this supports its use as a diagnostic method for quantifying micro-RNAs, particularly in large multi-center trials.[Abstract] [Full Text] [Related] [New Search]