These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evaluation of coated steroidal implants containing trenbolone acetate and estradiol-17β on live performance, carcass traits, and sera metabolites in finishing steers. Author: Smith ZK, Thompson AJ, Hutcheson JP, Nichols WT, Johnson BJ. Journal: J Anim Sci; 2018 May 04; 96(5):1704-1723. PubMed ID: 29534183. Abstract: Crossbred beef steers (n = 240; 12 pens/treatment; initial BW = 305 ± 17.7 kg) were used in a randomized block design feedlot study to evaluate the influence of coated trenbolone acetate (TBA) and estradiol-17β (E2) implants (Merck Animal Health, Madison, NJ) on gain performance, carcass traits, and sera metabolites. The five treatments were no implant (NI), Revalor-XR on d 0 [200 mg TBA + 20 mg E2 (coated); XR], Revalor-XS on d 0 [200 mg TBA + 40 mg E2 (total): 80 mg TBA + 16 mg E2 (noncoated) and 120 mg TBA + 24 mg E2 (coated); XS], Revalor-200 on d 0 [200 mg TBA + 20 mg E2 (noncoated); E200], or Revalor-200 on d 70 (D200). Interim BW and blood were collected on d 0, 14, 35, 70, 105, 140, and 175 prior to feeding and on d 213 prior to shipping. Following a 24 h clot at 4 °C, sera was harvested to quantify circulating E2, IGF-I, NEFA, serum urea-N (SUN), and 17β-trenbolone (17β-TbOH). Implanted steers had greater (P ≤ 0.05) ADG, G:F, and final BW than NI controls. Implants increased (P < 0.05) HCW by 8%, 366 vs. 391, 414, 380, and 396 ± 6.4 kg, for NI vs. XR, XS, E200, and D200, respectively. The greatest (P ≤ 0.05) dressing percentage, yield grade, and calculated empty body fat occurred in XS, which had greater (P < 0.05) rib fat than NI, XR, and D200. Marbling scores in NI were greater (P < 0.05) than E200 and D200; steers in XR and XS were intermediate (P > 0.10), not differing from NI, E200, or D200. An implant × day interaction (P ≤ 0.01) was noted for circulating E2, IGF-I, SUN, and 17β-TbOH. Implanted steers had elevated (P ≤ 0.05) sera E2, IGF-I, and 17β-TbOH, and decreased (P < 0.05) SUN following implantation compared to NI controls. Serum NEFA differed (P < 0.01) over time, but did not differ (P > 0.10) due to implant treatment. These data indicated that the polymer coating applied to the XR implant delayed release of steroidal hormones congruently to D200, with no negative impact on marbling. The greatest dose of E2, contained in XS, provided improvements in gain and carcass weight without detriment to marbling scores compared to NI.[Abstract] [Full Text] [Related] [New Search]