These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: An evaluation of distal hair cortisol concentrations collected at delivery. Author: Orta OR, Tworoger SS, Terry KL, Coull BA, Gelaye B, Kirschbaum C, Sanchez SE, Williams MA. Journal: Stress; 2018 Jul; 21(4):355-365. PubMed ID: 29614892. Abstract: Distal hair segments collected at delivery may allow for the assessment of maternal cortisol secretion in early pregnancy, an important time window for fetal development. Therefore, an investigation of the validity of distal hair cortisol concentrations is warranted. We examined the concordance between proximal and distal hair cortisol concentrations (HCC), both representing the first trimester of pregnancy. The study population was comprised of a random sample of 97 women participating in the Pregnancy Outcomes Maternal and Infant Study, a prospective cohort study of pregnant women attending prenatal clinics in Lima, Peru. Each participant provided two hair samples: once at enrollment [mean gestational age (GA) = 13.1 weeks] and again at full-term delivery (mean GA = 39.0 weeks). Hair segments reflecting the first trimester were: 3 cm hair segments closest to the scalp on the first hair sample (proximal) and 6-9 cm from the scalp on the second hair sample (distal). HCC was determined using Luminescence Immunoassay. A subset (N = 28) had both hair segments additionally analyzed using liquid chromatography tandem mass spectrometry (LC-MS/MS). HCC values were log-transformed (logHCC), and proximal-distal differences tested using paired sample t-tests. Concordance was evaluated within and across assay types. LogHCC, measured using immunoassay, in distal hair segments was lower compared to proximal hair segments (1.35 versus 1.64 respectively; p = .02). No difference was observed using LC-MS/MS (1.99 versus 1.83, respectively; p=.33). Proximal-distal concordance was low within assay (immunoassay: Pearson = 0.27 and κ = 0.10; LC-MS/MS: Pearson = 0.37 and κ = 0.07). High correlation was observed across assays for both distal (Pearson = 0.78, p < .001; κ = 0.64) and proximal segments (Pearson = 0.96, p < .001; κ = 0.75). In conclusion, distal first-trimester hair segments collected at delivery have lower absolute HCC compared to HCC in proximal first trimester hair segments collected in early pregnancy, and are poorly concordant with HCC in proximal segments. Findings may inform the design of future studies.[Abstract] [Full Text] [Related] [New Search]