  • Title: Light localization with low-contrast targets in a patient implanted with a suprachoroidal-transretinal stimulation retinal prosthesis.
    Author: Endo T, Fujikado T, Hirota M, Kanda H, Morimoto T, Nishida K.
    Journal: Graefes Arch Clin Exp Ophthalmol; 2018 Sep; 256(9):1723-1729. PubMed ID: 29679170.
    Abstract:
    PURPOSE: To evaluate the improvement in targeted reaching movements toward targets of various contrasts in a patient implanted with a suprachoroidal-transretinal stimulation (STS) retinal prosthesis. METHODS: An STS retinal prosthesis was implanted in the right eye of a 42-year-old man with advanced Stargardt disease (visual acuity: right eye, light perception; left eye, hand motion). In localization tests during the 1-year follow-up period, the patient attempted to touch the center of a white square target (visual angle, 10°; contrast, 96, 85, or 74%) displayed at a random position on a monitor. The distance between the touched point and the center of the target (the absolute deviation) was averaged over 20 trials with the STS system on or off. RESULTS: With the left eye occluded, the absolute deviation was not consistently lower with the system on than off for high-contrast (96%) targets, but was consistently lower with the system on for low-contrast (74%) targets. With both eyes open, the absolute deviation was consistently lower with the system on than off for 85%-contrast targets. With the system on and 96%-contrast targets, we detected a shorter response time while covering the right eye, which was being implanted with the STS, compared to covering the left eye (2.41 ± 2.52 vs 8.45 ± 3.78 s, p < 0.01). CONCLUSIONS: Performance of a reaching movement improved in a patient with an STS retinal prosthesis implanted in an eye with residual natural vision. Patients with a retinal prosthesis may be able to improve their visual performance by using both artificial vision and their residual natural vision. CLINICAL TRIAL REGISTRATION: Beginning date of the trial: Feb. 20, 2014 Date of registration: Jan. 4, 2014 Trial registration number: UMIN000012754 Registration site: UMIN Clinical Trials Registry (UMIN-CTR) http://www.umin.ac.jp/ctr/index.htm.
    [Abstract] [Full Text] [Related] [New Search]