These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: In-Line Filtration Reduces Postoperative Venous Peripheral Phlebitis Associated With Cannulation: A Randomized Clinical Trial. Author: Villa G, Chelazzi C, Giua R, Tofani L, Zagli G, Boninsegni P, Pinelli F, De Gaudio AR, Romagnoli S. Journal: Anesth Analg; 2018 Dec; 127(6):1367-1374. PubMed ID: 29697508. Abstract: BACKGROUND: Peripheral venous cannulation is an everyday practice of care for patients undergoing anesthesia and surgery. Particles infused with intravenous fluids (eg, plastic/glass/drugs particulate) contribute to the pathogenesis of peripheral phlebitis. The aim of this study is to demonstrate the efficacy of in-line filtration in reducing the incidence of postoperative phlebitis associated with peripheral short-term vascular access. METHODS: In this controlled trial, 268 surgical patients were randomly assigned to in-line filtration and standard care (NCT03193827). The incidence of phlebitis (defined as visual infusion phlebitis [VIP] score, ≥2) within 48 hours was compared between the 2 groups, as well as the onset and severity of phlebitis and the reasons for removal of the cannula. The lifespan of venous cannulae was compared for the in-line filter and no-filter groups through a Kaplan-Meier curve. RESULTS: The incidence of phlebitis within 48 hours postoperatively was 2.2% and 26.9% (difference, 25% [95% confidence interval {CI}, 12%-36%]; odds ratio, 0.05 [0.01-0.15]), respectively, for the in-line filter and no-filter groups (P < .001). From 24 to 96 hours postoperatively, patients in the no-filter group had higher VIP scores than those in in-line filter group (P < .001). Venous cannulae in the in-line filter group exhibited prolonged lifespan compared to those in the no-filter group (P = .01). In particular, 64 (47.8%) of cannulae in the in-line filter group and 56 (41.8%) of those in the no-filter group were still in place at 96 hours postoperatively. At the same time point, patients with a VIP score <3 were 100% in the in-line filter group and only 50% for the no-filter group. In-line filtration was a protective factor for postoperative phlebitis (hazard ratio, 0.05 [95% CI, 0.014-0.15]; P < .0001) and cannula removal (hazard ratio, 0.7 [95% CI, 0.52-0.96]; P = .02). CONCLUSIONS: In-line filtration has a protective effect for postoperative phlebitis and prolongs cannula lifespan during peripheral venous cannulation in surgical patients.[Abstract] [Full Text] [Related] [New Search]