These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Development of an Abbreviated Mycophenolic Acid Area Under the Time-Concentration Curve for Renal Transplant Patients Under Enteric-Coated Mycophenolate Sodium: A Comparison With Critical Analysis of Available Equations. Author: David-Neto E, Triboni AH, Ramos F, Agena F, Romano P. Journal: Ther Drug Monit; 2018 Aug; 40(4):411-416. PubMed ID: 29746396. Abstract: BACKGROUND: Enteric-coated mycophenolate sodium is frequently used in renal transplantation. The pharmacokinetic profile of mycophenolic acid (MPA) shows a broad range of time-to-maximum concentration (Tmax) that limits the use of a single MPA concentration to calculate the area under the time-concentration curve (AUC). For both research and clinical MPA monitoring, measuring a complete AUC is troublesome to the center and patients. METHODS: We obtained 171 complete MPA-AUC12h (0, 20, 40, 60, 90, 120, 180, 240, 360, 480, 600, and 720 minutes) from 59 adult (54 ± 16 years) patients (29 men and 43 whites) who have been receiving stable doses of tacrolimus/enteric-coated mycophenolate sodium and steroids. We used the 59 curves drawn at 31 ± 4 days after transplantation to develop the abbreviated equations, and the remaining 112 curves drawn at 109 ± 59 days were used to validate them. We used 5 other proposed equations to estimate MPA-AUC (eAUC) (4 with enzyme-multiplied immunoassay technique assay and one with high-performance liquid chromatography [HPLC]) and then used these results to compare with our measured AUC, the bias, and the 10% and 30% accuracy. MPA was measured by ultraperformance liquid chromatography coupled to a tandem mass spectrometry, and AUC was calculated by the trapezoidal rule. RESULTS: For both MPA-measuring methods, enzyme-multiplied immunoassay technique and ultraperformance liquid chromatography coupled to a tandem mass spectrometry, the Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) equations, and others that measure MPA up to 6 hours after the dose had an acceptable low bias with more results in the 10%-30% range than those using data collected until 4 hours. A highly adequate eAUC is obtained using blood collected at 8 hours. CONCLUSIONS: This analysis offers blood-sampling alternatives for MPA monitoring depending on the precision needed.[Abstract] [Full Text] [Related] [New Search]