These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evaluation of the fit of metal copings fabricated using stereolithography. Author: Kim SB, Kim NH, Kim JH, Moon HS. Journal: J Prosthet Dent; 2018 Nov; 120(5):693-698. PubMed ID: 29807735. Abstract: STATEMENT OF PROBLEM: Rapid prototyping, including stereolithography (SLA), is a more recent technique for fabricating metal frameworks than the conventional lost-wax technique. However, investigations of the marginal discrepancies and internal spacing of cobalt-chromium (Co-Cr) metal copings fabricated using SLA are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the clinical acceptability of the marginal discrepancies and internal spacing of Co-Cr metal copings fabricated using the SLA technique. MATERIAL AND METHODS: A resin tooth of a maxillary right first premolar was prepared with a deep chamfer margin for a metal-ceramic crown. Titanium master dies were milled after scanning the prepared tooth (n=45). In conventional lost wax group (group LW), the conventional lost-wax technique was used to fabricate Co-Cr metal copings (n=15). In milling group (group MC), a computer-aided design (CAD) system was used to design the metal copings, which were milled from Co-Cr alloy (n=15). The CAD system was also used to design the metal copings in a 3D-printed group (group SL), and Co-Cr metal copings were cast from resin patterns fabricated using the SLA device (n=15). Marginal discrepancies and internal spaces were measured using an optical microscope at ×100 magnification at 11 reference points. The values were analyzed statistically with 1-way analysis of variance (α=.05). RESULTS: The mean (±SD) overall space was 63.2 ±16.6 μm for group LW, 70.2 ±15.5 μm for group SL, and 130.3 ±13.8 μm for group MC. The overall spaces differed significantly between group MC and the other 2 groups (P<.05). The marginal discrepancy and internal spaces were significantly larger in group MC than in groups LW and SL. (P<.05). Occlusal spaces differed significantly among the 3 study groups (P<.05). CONCLUSIONS: Co-Cr metal copings fabricated using an SLA technique showed clinically acceptable marginal discrepancies and internal spaces. These spaces did not differ significantly from those obtained with the conventional lost-wax technique.[Abstract] [Full Text] [Related] [New Search]