These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences.
    Author: Wang KY, Uribe TA, Lincoln CM.
    Journal: Clin Imaging; 2018; 51():229-234. PubMed ID: 29879598.
    Abstract:
    PURPOSE: Infratentorial lesions in patients with multiple sclerosis are associated with long-term disability. Two-dimensional fluid-attenuated inversion recovery demonstrates poor infratentorial lesion detection when compared to T2-weighted spin echo. Evidence of improved detection with 3D fluid-attenuated inversion recovery has been conflicting. This study compares the infratentorial lesion detection performance, observer performance, and signal and contrast properties between T2-weighted spin echo, 2D, and 3D fluid-attenuated inversion recovery. METHODS: Two board-certified radiologists independently reviewed and counted infratentorial lesions from 85 brain MRIs in patients with clinically definite multiple sclerosis and concurrent 3D, 2D fluid-attenuated inversion recovery, and T2-weighted spin echo sequences. Contrast-to-noise and signal-to-noise ratios were measured for 25 MRIs. Wilcoxon signed-rank test was used for pairwise comparisons of the combined average infratentorial lesion count, contrast-to-noise, and signal-to-noise ratios, and was adjusted for three pairwise comparisons using Bonferroni correction. A corrected p value < 0.05 was considered statistically significant. RESULTS: The number of lesions on 3D fluid-attenuated inversion recovery was significantly higher than those on 2D (p < 0.001) and T2-weighted spin echo (p < 0.001). Results of contrast-to-noise and signal-to-noise ratios were overall mixed and predominantly not concordant with lesion count findings, with T2-weighted spin echo demonstrating the highest signal-to-noise ratios and contrast-to-noise ratio of lesion compared with white matter but the lowest contrast-to-noise ratio of lesion compared with gray matter. CONCLUSION: The 3D fluid-attenuated inversion recovery sequence addresses the disadvantage of poor infratentorial lesion detection on 2D, while still maintaining the advantage over T2-weighted spin echo in the detection of lesions adjacent to the cerebrospinal fluid.
    [Abstract] [Full Text] [Related] [New Search]