These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Catheter-assisted 360-Degree Trabeculotomy for Congenital Glaucoma.
    Author: Toshev AP, Much MM, Klink T, Pfeiffer N, Hoffmann EM, Grehn F.
    Journal: J Glaucoma; 2018 Jul; 27(7):572-577. PubMed ID: 29965889.
    Abstract:
    PURPOSE: To determine feasibility, efficacy, and safety of ab externo 360-degree trabeculotomy with illuminated microcatheter for congenital glaucoma. PATIENTS AND METHODS: The postoperative results of 36 eyes in 23 consecutive patients who underwent 360-degree trabeculotomy for primary congenital glaucoma (PCG) or secondary congenital glaucoma using an illuminated microcatheter were retrospectively analyzed. Success criteria were defined as intraocular pressure (IOP) ≤18 mm Hg without (complete success) and with medication (qualified success). RESULTS: In all previously nonoperated eyes with PCG (group 1), the Schlemm's canal was identified and circumferentially cannulated for 360-degree trabeculotomy. In group 2 comprising of operated eyes with PCG and eyes with secondary congenital glaucoma, the performance of 360-degree trabeculotomy failed in 4 eyes because of the Schlemm's canal occlusion or high tissue resistance of the trabecular meshwork. Mean preoperative IOP was 28.6±5 and 29.6±9 mm Hg with 7 of 20 eyes and 7 of 9 eyes receiving IOP-lowering medication in group 1 and group 2, respectively. Mean postoperative IOP was reduced to 13±2.7 and 20.2±7.1 mm Hg after a mean follow-up of 15.3 and 12.7 months with 4 of 20 eyes and 5 of 9 eyes receiving medication in group 1 and group 2, respectively. Four eyes underwent further surgery. Complete success was achieved in 16 and 3 eyes, whereas qualified success was achieved in 20 and 4 eyes from group 1 and group 2, respectively. In all eyes, a mild to moderate postoperative hyphema was observed. CONCLUSIONS: Ab externo catheter-assisted 360-degree trabeculotomy controls IOP in a majority of patients with congenital glaucoma after a single operation. Moderate blood reflux in the anterior chamber is considered as a common postoperative finding. We did not observe hypotony or other severe complications in our series. In 1 patient, we experienced catheter misdirection in an eye that had previously undergone trabeculotomy.
    [Abstract] [Full Text] [Related] [New Search]