These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Perivascular Spaces Volume in Sporadic and Hereditary (Dutch-Type) Cerebral Amyloid Angiopathy.
    Author: Martinez-Ramirez S, van Rooden S, Charidimou A, van Opstal AM, Wermer M, Gurol ME, Terwindt G, van der Grond J, Greenberg SM, van Buchem M, Viswanathan A.
    Journal: Stroke; 2018 Aug; 49(8):1913-1919. PubMed ID: 30012821.
    Abstract:
    Background and Purpose- Magnetic resonance imaging visible perivascular spaces in the centrum semiovale (CSO-PVS) have been associated with cerebral amyloid angiopathy (CAA).We aimed to further confirm this link by evaluating CSO-PVS volume in pathologically-demonstrated sporadic and genetically-demonstrated hereditary forms of the disease. Methods- We studied a retrospective hospital-based cohort consisting of 63 individuals aged >55 having brain magnetic resonance imaging and pathological assessment of CAA (mean age, 73.6±8.5; 46% female), and a separate cohort consisting of 26 carriers, and 28 noncarriers of the hereditary cerebral hemorrhage with amyloidosis-Dutch type (mean age, 46.7±12.8; 61.1% female). CSO-PVS volume was quantified on a single magnetic resonance imaging slice using a computer-assisted segmentation method and expressed as the relative volume of the intracranial volume in that particular slice (CSO-PVS relative volume). We compared CSO-PVS relative volume (1) between subjects with and without the disease in both cohorts; (2) between non-CAA, CAA without hemorrhage, and CAA with hemorrhage cases in the sporadic CAA cohort. All variables reaching P<0.1 in bivariate analyses were entered in logistic regression models. Results- In both sporadic and Dutch cohorts, cases with CAA had significantly higher CSO-PVS relative volume than cases without (median [IQR]: 3.7% [2.5-5.3] versus 1.8% [1.2-2.4], P<0.0001; 3.8% [0.6-6.2] versus 0.7% [0.4-1.6], P=0.007; respectively). In linear regression models, sporadic CAA was associated with higher CSO-PVS relative volume ( P=0.008). In the sporadic CAA cohort, compared with non-CAA cases, CSO-PVS relative volume was higher in both CAA with hemorrhage and without hemorrhage (4.4% [2.6-6.1] and 3% [2.4-3.6] versus 1.8% [1.2-2.4], P<0.001 and P=0.005, respectively). Higher CSO-PVS relative volume was associated with CAA in regression models, both when hemorrhage was present (odds ratio, 2.63; [95% confidence interval, 1.33-5.18]; P=0.005) and absent (odds ratio, 4.55; [95% confidence interval, 0.98-21.04]; P=0.05). Conclusions- Increased CSO-PVS volume is a consistent magnetic resonance imaging marker of cerebrovascular amyloid deposition and a promising diagnostic tool for sporadic CAA without hemorrhagic manifestations.
    [Abstract] [Full Text] [Related] [New Search]