These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Performance of the EUCAST disc diffusion method and two MIC methods in detection of Enterobacteriaceae with reduced susceptibility to meropenem: the NordicAST CPE study. Author: Haldorsen B, Giske CG, Hansen DS, Helgason KO, Kahlmeter G, Löhr IH, Matuschek E, Österblad M, Rantakokko-Jalava K, Wang M, Småbrekke L, Samuelsen Ø, Sundsfjord A, NordicAST CPE Study Group. Journal: J Antimicrob Chemother; 2018 Oct 01; 73(10):2738-2747. PubMed ID: 30053113. Abstract: OBJECTIVES: To examine performance of EUCAST disc diffusion and supplementary MIC methods for detection of Enterobacteriaceae with reduced susceptibility to meropenem using EUCAST screening recommendations. METHODS: Sixty-one Nordic laboratories delivered data on EUCAST disc diffusion (n = 61), semi-automated meropenem MIC (n = 23; VITEK2, n = 20 and Phoenix, n = 3) and gradient meropenem MIC (n = 58) methods. The strains (n = 27) included the major carbapenemase classes (A, n = 4; B, n = 9; D, n = 6) involved in the global spread of carbapenemase-producing Enterobacteriaceae (CPE) and non-CPE strains (n = 8) covering a range of broth microdilution (BMD) meropenem MICs. RESULTS: A triplicate Klebsiella variicola (meropenem MIC 0.5 mg/L) harbouring OXA-48 and Escherichia coli ATCC 25922 showed an overall good precision. Meropenem zone diameters below the EUCAST screening cut-off (<27 mm) were reported for strains with MIC ≥1 mg/L (n = 21), irrespective of resistance mechanism. For three strains (MIC = 0.5 mg/L) with OXA-48/-181, eight laboratories provided meropenem zone diameters above the screening cut-off. Very major errors (VMEs) were not observed. The overall distributions of major errors (MEs) and minor errors (mEs) were 9% and 36% (disc diffusion), 26% and 18% (VITEK2) and 7% and 20% (gradient MIC), respectively. Differences in ME and mE distributions between disc diffusion and MIC gradient tests compared with semi-automated methods were significant (P < 0.0001), using BMD MICs as a reference for categorization. CONCLUSIONS: The EUCAST disc diffusion method is a robust method to screen for CPE but isolates with meropenem MICs <1 mg/L pose challenges. The high ME rate in semi-automated methods might deter appropriate use of carbapenems in CPE infections with limited therapeutic options.[Abstract] [Full Text] [Related] [New Search]