These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Free energy coupling between H+-generating and H+-consuming pumps. Ratio between output and input forces.
    Author: Petronilli V, Pietrobon D, Zoratti M, Azzone GF.
    Journal: Eur J Biochem; 1986 Mar 03; 155(2):423-31. PubMed ID: 3007129.
    Abstract:
    The delta Gp/delta mu H ratio has been measured in mitochondria close to state 4 in the presence of various uncoupler or K+/valinomycin concentrations in media containing either 1 mM or 50 mM Pi. Care has been taken to control the factors affecting delta Gp and delta mu H which could lead to an artefactual increase of the delta Gp/delta mu H ratio above the highest accepted value for the H+/ATP stoichiometry (n = 4, synthesis + transport). In particular, to avoid overestimation of delta Gp due to inactivation of the ATPases at low delta mu H or to the presence of adenylate kinase, the static head state was approached from the side of net ATP synthesis and delta Gp was measured in a state close to static head but still maintaining a residual rate of aerobic phosphorylation. For each concentration of uncoupler or K+, the Pi concentration and/or the adenylate energy charge (EC) as a function of time have been measured as indicators of net ATP synthesis. Only the values of delta Gp measured during a decrease in Pi concentration and/or an increase in EC have been considered to be meaningful for calculations of delta Gp/delta mu H ratios. Both uncouplers and K+ transport cause a marked depression of delta mu H and a parallel depression of the rate of ATP synthesis. However the low rate of ATP synthesis taking place under conditions of low delta mu H eventually results, especially at high Pi concentrations, in a relatively large delta Gp. The delta Gp/delta mu H ratios obtained at the lower delta mu H values exceed 4 and approach 6. Although slightly higher delta Gp/delta mu H ratios are obtained with valinomycin-treated than with uncoupler-treated mitochondria, the pattern of the rise of the force ratio as delta mu H decreases is similar in both cases. An increase of the delta Gp/delta mu H ratio above 4, the maximal accepted H+/ATP stoichiometry is thermodynamically incompatible with the delocalized protonic coupling model.
    [Abstract] [Full Text] [Related] [New Search]