These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: 3D R2* mapping of the placenta during early gestation using free-breathing multiecho stack-of-radial MRI at 3T. Author: Armstrong T, Liu D, Martin T, Masamed R, Janzen C, Wong C, Chanlaw T, Devaskar SU, Sung K, Wu HH. Journal: J Magn Reson Imaging; 2019 Jan; 49(1):291-303. PubMed ID: 30142239. Abstract: BACKGROUND: Multiecho gradient-echo Cartesian MRI characterizes placental oxygenation by quantifying R2* . Previous research was performed at 1.5T using breath-held 2D imaging during later gestational age (GA). PURPOSE: To evaluate the accuracy and repeatability of a free-breathing (FB) 3D multiecho gradient-echo stack-of-radial technique (radial) for placental R2* mapping at 3T and report placental R2* during early GA. STUDY TYPE: Prospective. POPULATION: Thirty subjects with normal pregnancies and three subjects with ischemic placental disease (IPD) were scanned twice: between 14-18 and 19-23 weeks GA. FIELD STRENGTH: 3T. SEQUENCE: FB radial. ASSESSMENT: Linear correlation (concordance coefficient, ρc ) and Bland-Altman analyses (mean difference, MD) were performed to evaluate radial R2* mapping accuracy compared to Cartesian in a phantom. Radial R2* mapping repeatability was characterized using the coefficient of repeatability (CR) between back-to-back scans. The mean and spatial coefficient of variation (CV) of R2* was determined for all subjects, and separately for anterior and posterior placentas, at each GA range. STATISTICAL TESTS: ρc was tested for significance. Differences in mean R2* and CV were tested using Wilcoxon Signed-Rank and Rank-Sum tests. P < 0.05 was considered significant. Z-scores for the IPD subjects were determined. RESULTS: FB radial demonstrated accurate (ρc ≥0.996; P < 0.001; |MD|<0.2s-1 ) and repeatable (CR<4s-1 ) R2* mapping in a phantom, and repeatable (CR≤4.6s-1 ) R2* mapping in normal subjects. At 3T, placental R2* mean ± standard deviation was 12.9s-1 ± 2.7s-1 for 14-18 and 13.2s-1 ± 1.9s-1 for 19-23 weeks GA. The CV was significantly greater (P = 0.043) at 14-18 (0.63 ± 0.12) than 19-23 (0.58 ± 0.13) weeks GA. At 19-23 weeks, the CV was significantly lower (P < 0.001) for anterior (0.49 ± 0.08) than posterior (0.67 ± 0.11) placentas. One IPD subject had a lower mean R2* than normal subjects at both GA ranges (Z<-2). DATA CONCLUSION: FB radial provides accurate and repeatable 3D R2* mapping for the entire placenta at 3T during early GA. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:291-303.[Abstract] [Full Text] [Related] [New Search]