These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A glassy carbon electrode modified with a composite consisting of gold nanoparticle, reduced graphene oxide and poly(L-arginine) for simultaneous voltammetric determination of dopamine, serotonin and L-tryptophan.
    Author: Khan MZH, Liu X, Tang Y, Zhu J, Hu W, Liu X.
    Journal: Mikrochim Acta; 2018 Aug 30; 185(9):439. PubMed ID: 30167981.
    Abstract:
    A glassy carbon electrode (GCE) was modified with poly(L-arginine) (P-Arg), reduced graphene oxide (rGO) and gold nanoparticle (AuNP) to obtain an electrode for simultaneous determination of dopamine (DA), serotonin (5-HT) and L-tryptophan (L-Trp) in the presence of ascorbic acid (AA). The modified GCE was prepared via subsequent 'layer-by-layer' deposition using an electrochemical technique. The surface morphology of the modified electrode was studied by scanning electron microscopy, and electrochemical characterizations were carried out via cyclic voltammetry and electrochemical impedance spectroscopy. The modified electrode showed excellent electrocatalytic activity toward DA, 5-HT and L-Trp at pH 7.0. Figures of merit for the differential pulse voltammetric reponse are as follows: (a) Response to DA is linear in two intervals, viz. 1.0-50 nM and 1.0-50 μM DA concentration range, the typical working voltage is 202 mV (vs. Ag/AgCl), and the detection limit is 1 nM (at an S/N ratio of 3). For 5-HT, the respective data are 10 to 500 nM and 1.0 to 10 μM, 381 mV, and 30 nM. For L-Trp, the respective data are 10-70 nM and 10-100 μM, 719 mV, and 0.1 μM. The modified GCE is fairly selective. It was successfully applied to the simultaneous determination of DA, 5-HT, and L-Trp in spiked urine samples, and high recovery rates were found. Graphical abstract Schematic presentation of the voltammetric sensor based on a glassy carbon electrode modified with poly(L-arginine), reduced graphene oxide (rGO) and gold nanoparticle (GCE/P-Arg/ErGO/AuNP) for simultaneous determination of dopamine (DA), serotonin (5-HT) and L-tryptophan (L-Trp).
    [Abstract] [Full Text] [Related] [New Search]