These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Practice Pattern Variation in the Use of Transesophageal Echocardiography for Open Valve Cardiac Surgery. Author: MacKay EJ, Groeneveld PW, Fleisher LA, Desai ND, Gutsche JT, Augoustides JG, Patel PA, Neuman MD. Journal: J Cardiothorac Vasc Anesth; 2019 Jan; 33(1):118-133. PubMed ID: 30174265. Abstract: OBJECTIVE: The authors sought to assess for the presence of practice variation in the use of intraoperative transesophageal echocardiography (TEE) for open cardiac valve surgery. DESIGN: This study was a retrospective cohort analysis. SETTING: The administrative claims data used for this investigation were multi-institutional and a representative sample of commercially insured patients in the United States between 2010 and 2015. PARTICIPANTS: The cohort consisted of adult patients, aged 18 years or older, undergoing open mitral valve (MV) or aortic valve (AV) surgery. INTERVENTIONS: This was an observational analysis without interventions. MEASUREMENTS AND MAIN RESULTS: Of 19,386 valve surgeries, 12,313 (64%) underwent AV replacement, 6,192 (32%) underwent MV repair or replacement, and 881 (<5%) underwent both MV and AV surgery. The overall rate of intraoperative TEE was 82% (95% confidence interval [CI]: 81%-82%), less frequently observed in AV procedures compared to MV or combined MV-AV procedures (80% v 85%, p < 0.001). Rates of intraoperative TEE claims varied markedly across U.S. states. After adjustment, the relative odds of an intraoperative TEE claim ranged across states from 0.26 (Louisiana, 95% CI: 0.18-0.36; p < 0.001) to 2.10 (North Carolina, 95% CI: 1.57-2.82; p < 0.001). CONCLUSION: Among adult patients undergoing open AV or MV surgery in the United States, 82% had a claim for an intraoperative TEE with marked variability across U.S. states. Increasing adherence to intraoperative TEE guidelines for valve surgery may represent an unrecognized opportunity to improve the quality of cardiac surgical care.[Abstract] [Full Text] [Related] [New Search]