These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Effect of a noise-optimized virtual monoenergetic reconstruction technique on dual-energy CT for image quality of inflammatory bowel disease].
    Author: Yang H, Wu X, Jiang B, Deng K, Sun J, Mei X.
    Journal: Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2018 Aug 28; 43(8):875-881. PubMed ID: 30197316.
    Abstract:
    To assess the value of noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique on objective and subjective image quality in patients with inflammatory bowel disease (IBD) undergoing abdominal dual-energy computed tomography (DECT).
 Methods: Datasets from 32 patients (22 men, 10 women) with IBD, who underwent abdominal DECT, were reconstructed by using the standard linearly blended (M_0.6), traditional monoenergetic (VMI) and VMI+ algorithms in 10-keV intervals from 40-100 keV. Attenuation in IBD lesions was measured to perform objective evaluation using signal-to-noise (SNR) and contrast-to-noise ratios (CNR). Subjective evaluation was performed by 3 independent blinded radiologists using 5-point Likert scales. The overall image quality, image sharpness, lesion delineation, and image noise were analyzed. 
 Results: Mean SNR and CNR peaked at 40 keV VMI+ series (SNR 8.28±2.34, CNR 5.10±2.10) and they were significantly higher than those in linearly blended (SNR 5.82±1.44, CNR 1.53±0.86) and all VMI series (all P<0.01). Subjective image parameter was the highest for the 50 keV VMI+ series regarding overall image quality (mean 4.80, all P<0.01). The highest image sharpness scores were observed at 40 and 50 keV VMI+ reconstructions (mean 4.14 and 4.25, respectively; P=0.415). VMI+ series at 40 keV provided the highest lesion delineation (mean 4.52, all P<0.01). Image noise was low at the 100 keV VMI+ and VMI series (mean 4.58 and 4.40, respectively; P≥0.11).
 Conclusion: Low-keV VMI+ reconstructions improves SNR, CNR, and subjective image quality significantly in patients with IBD. 目的:评估炎症性肠病(inflammatory bowel disease,IBD)患者腹部双能量CT(dual-energy CT,DECT)扫描不同能级噪声优化的虚拟单能量图像(noise-optimized virtual monoenergetic imaging,VMI+)的主观和客观图像质量,得出最佳重建参数,提高IBD诊断准确率。方法:选取2016年4月到2017年6月确诊为IBD的32名患者腹部DECT扫描图像进行线性融合(M_0.6)、VMI+、传统虚拟单能量图像(virtual monoenergetic imaging,VMI)重建,虚拟能级为40~100 keV,间隔为10 keV。以病变肠段部位的图像信噪比(signal-to-noise ratio,SNR)和对比噪声比(contrast-to-noise ratio,CNR)作为客观图像质量评价标准,主观图像质量评价由3名放射科医生对总体图像质量、锐利度、病变轮廓、噪声4个方面进行双盲评估。结果:客观图像质量评价最佳重建参数为40 keV VMI+(SNR 8.28±2.34;CNR 5.10±2.10),优于线性融合图像(SNR 5.82±1.44;CNR 1.53±0.86)和传统VMI(P<0.01)。主观图像质量评价中,50 keV VMI+总体图像质量(均值4.80)高于其他图像(P<0.01),40和50 keV VMI+锐利度最高(均值分别为4.14和4.25,P=0.415),40 keV VMI+显示病变轮廓能力评分高于其他图像(均值4.52,P<0.01)。100 keV VMI+和100 keV VMI噪声最低(均值分别为4.58和4.40,P≥0.11)。结论:相比于线性融合和传统VMI重建,低能级VMI+可显著提高IBD病变部位的腹部DECT扫描图像的主观和客观图像质量。.
    [Abstract] [Full Text] [Related] [New Search]