Title: [Effect of a noise-optimized virtual monoenergetic reconstruction technique on dual-energy CT for image quality of inflammatory bowel disease]. Author: Yang H, Wu X, Jiang B, Deng K, Sun J, Mei X. Journal: Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2018 Aug 28; 43(8):875-881. PubMed ID: 30197316. Abstract: To assess the value of noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique on objective and subjective image quality in patients with inflammatory bowel disease (IBD) undergoing abdominal dual-energy computed tomography (DECT). Methods: Datasets from 32 patients (22 men, 10 women) with IBD, who underwent abdominal DECT, were reconstructed by using the standard linearly blended (M_0.6), traditional monoenergetic (VMI) and VMI+ algorithms in 10-keV intervals from 40-100 keV. Attenuation in IBD lesions was measured to perform objective evaluation using signal-to-noise (SNR) and contrast-to-noise ratios (CNR). Subjective evaluation was performed by 3 independent blinded radiologists using 5-point Likert scales. The overall image quality, image sharpness, lesion delineation, and image noise were analyzed. Results: Mean SNR and CNR peaked at 40 keV VMI+ series (SNR 8.28±2.34, CNR 5.10±2.10) and they were significantly higher than those in linearly blended (SNR 5.82±1.44, CNR 1.53±0.86) and all VMI series (all P<0.01). Subjective image parameter was the highest for the 50 keV VMI+ series regarding overall image quality (mean 4.80, all P<0.01). The highest image sharpness scores were observed at 40 and 50 keV VMI+ reconstructions (mean 4.14 and 4.25, respectively; P=0.415). VMI+ series at 40 keV provided the highest lesion delineation (mean 4.52, all P<0.01). Image noise was low at the 100 keV VMI+ and VMI series (mean 4.58 and 4.40, respectively; P≥0.11). Conclusion: Low-keV VMI+ reconstructions improves SNR, CNR, and subjective image quality significantly in patients with IBD. 目的:评估炎症性肠病(inflammatory bowel disease,IBD)患者腹部双能量CT(dual-energy CT,DECT)扫描不同能级噪声优化的虚拟单能量图像(noise-optimized virtual monoenergetic imaging,VMI+)的主观和客观图像质量,得出最佳重建参数,提高IBD诊断准确率。方法:选取2016年4月到2017年6月确诊为IBD的32名患者腹部DECT扫描图像进行线性融合(M_0.6)、VMI+、传统虚拟单能量图像(virtual monoenergetic imaging,VMI)重建,虚拟能级为40~100 keV,间隔为10 keV。以病变肠段部位的图像信噪比(signal-to-noise ratio,SNR)和对比噪声比(contrast-to-noise ratio,CNR)作为客观图像质量评价标准,主观图像质量评价由3名放射科医生对总体图像质量、锐利度、病变轮廓、噪声4个方面进行双盲评估。结果:客观图像质量评价最佳重建参数为40 keV VMI+(SNR 8.28±2.34;CNR 5.10±2.10),优于线性融合图像(SNR 5.82±1.44;CNR 1.53±0.86)和传统VMI(P<0.01)。主观图像质量评价中,50 keV VMI+总体图像质量(均值4.80)高于其他图像(P<0.01),40和50 keV VMI+锐利度最高(均值分别为4.14和4.25,P=0.415),40 keV VMI+显示病变轮廓能力评分高于其他图像(均值4.52,P<0.01)。100 keV VMI+和100 keV VMI噪声最低(均值分别为4.58和4.40,P≥0.11)。结论:相比于线性融合和传统VMI重建,低能级VMI+可显著提高IBD病变部位的腹部DECT扫描图像的主观和客观图像质量。.[Abstract] [Full Text] [Related] [New Search]