These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Test-Retest Reliability Between Free Weight and Machine-Based Movement Velocities. Author: Miller RM, Freitas EDS, Heishman AD, Koziol KJ, Galletti BAR, Kaur J, Bemben MG. Journal: J Strength Cond Res; 2020 Feb; 34(2):440-444. PubMed ID: 30199448. Abstract: Miller, RM, Freitas, EDS, Heishman, AD, Koziol, KJ, Galletti, BAR, Kaur, J, and Bemben, MG. Test-retest reliability between free weight and machine-based movement velocities. J Strength Cond Res 34(2): 440-444, 2020-Several devices are available to measure muscular power through velocity measurement, including the Tendo FitroDyne. The ability for such devices to produce consistent results is still questioned, and the reproducibility of measurement between free weight and machine exercise has yet to be examined. Therefore, the aim of this investigation was to determine the test-retest reliability for barbell velocity during the bench press (BP) and weight velocity during the 2 leg press (2LP) for loads corresponding to 20-80% of 1 repetition maximum (1RM). Forty recreationally active individuals (22.6 ± 2.5 years; 175.9 ± 10.8 cm; and 76.2 ± 13.2 kg) with a 1RM BP and 2LP of 66.8 ± 32.4 kg and 189.5 ± 49 kg, respectively, volunteered for this study. Subjects completed 1 familiarization visit preceding 3 testing visits, which encompassed 1RM determination and 2 days of velocity testing. Forty-eight hours after 1RM testing, the subjects performed 1 repetition at 20, 30, 40, 50, 60, 70, and 80% of their 1RM for each exercise in randomized order. Subjects returned to the laboratory 1 week later to perform the velocity assessment again in randomized order. Intraclass correlation coefficient (ICC2,1) and relative SEM for the BP and 2LP ranged from 0.56 to 0.98 (3-18.1%) and 0.78 to 0.98 (2.8-7.2%), respectively, and no mean differences were observed between trials. The results suggest high reliability for BP velocity between 30 and 60% 1RM and moderate reliability at 20, 70, and 80% 1RM, while the 2LP displayed high to excellent reliability from 20 to 80% 1RM. Cumulatively, machine-based exercise displayed greater reproducibility; however, additional machine exercises need to be examined to bolster this conclusion.[Abstract] [Full Text] [Related] [New Search]