These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Terrestrial humic-like fluorescence peak of chromophoric dissolved organic matter as a new potential indicator tracing the antibiotics in typical polluted watershed. Author: Li S, Ju H, Ji M, Zhang J, Song K, Chen P, Mu G. Journal: J Environ Manage; 2018 Dec 15; 228():65-76. PubMed ID: 30212676. Abstract: Natural surface waters are threatened globally by antibiotics pollution. In this study, we analyzed antibiotics and CDOM (Chromophoric dissolved organic matter) fluorescence in different water bodies using HPLC method and Excitation Emission Matrix- Parallel factor analysis, respectively. A combination of field studies in the Yinma River Watershed were conducted in rivers, reservoirs and urban rivers, and 65 CDOM and antibiotic samples were taken in April, May, July, and August 2016. EEM-PARAFAC analysis identified two components; a humic-like (C1) component and a tryptophan-like (C2) component. The redundancy analysis (RDA) demonstrated that CDOM could explain 38.2% (two axes) of the five antibiotics in reservoirs (N = 31), and 26.0% (two axes) of those in rivers and urban water (N = 30). Furthermore, the Pearson correlation coefficient between Sulfamethoxazole and C1 in reservoir water was 0.91 (t-test, 2-tailed, p < 0.01), and that between Sulfamethoxazole and C2 was 0.68 (t-test, 2-tailed, p < 0.01). This indicated that the humic-like component of CDOM PARAFAC fluorescence could detect Sulfamethoxazole contamination levels in the homogenized reservoir waters. Our results identified Sulfamethoxazole and Quinolones (Norfloxacin, 16.5 ng L-1; Enrofloxacin, 0.3 ng L-1; Ciprofloxacin, 30.9 ng L-1) at mean concentrations of 369.5 ng L-1 and 15.9 ng L-1, respectively, which were the higher levels in natural surface waters. The FTIR spectroscopy of the mixture of humic acid and sulfamethoxazole showed that the absorbance at 3415 cm-1 linked to OH stretching of OH groups and at 1386 cm-1 because of OH bending and vibration of COOH groups became weaker, indicating that COOH groups of humic acid can adsorb and react with -NH2 of sulfamethoxazole. The CDOM PARAFAC components can be adapted for online or in situ fluorescence measurements as an early warning of Sulfamethoxazole distribution and contamination in similar aquatic environments.[Abstract] [Full Text] [Related] [New Search]