These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evaluation of sex-specific cut-off values of high-sensitivity cardiac troponin I and T assays in an emergency department setting - Results from the Linz Troponin (LITROP) study.
    Author: Mueller T, Egger M, Peer E, Jani E, Dieplinger B.
    Journal: Clin Chim Acta; 2018 Dec; 487():66-74. PubMed ID: 30227114.
    Abstract:
    BACKGROUND: The aim of the present analysis was to evaluate sex-specific cut-off values of a high-sensitivity cardiac troponin T (hs-cTnT) assay and a high-sensitivity cardiac troponin I (hs-cTnI) assay in an emergency department setting. METHODS: We retrospectively studied 1945 male and 1643 female emergency department patients in whom we had measured both Roche hs-cTnT and Abbott hs-cTnI routinely upon every troponin measurement request. We performed reclassification analyses of sex-specific thresholds versus sex-neutral thresholds of both assays. In addition, we performed sensitivity analyses to find those sex-specific cut-off values for the Roche hs-cTnT and the Abbott hs-cTnI assays with the lowest possible rate of discordant classifications by both assays. RESULTS: Compared with the classification by the sex-neutral thresholds (i.e., 14 ng/L for hs-cTnT and 26 ng/L for hs-cTnI), using sex-specific thresholds (i.e., 16 ng/L in males and 9 ng/L in females for hs-cTnT; and in 34 ng/L males and 16 ng/L in females for hs-cTnI) resulted in a total reclassification rate of 4% for hs-cTnT and 3% for hs-cTnI in male individuals, and of 11% and 6%, respectively, in female individuals. In our cohort, the sex-specific hs-cTnT cut-off values currently in use (i.e., 16 ng/L in males and 9 ng/L in females) were best matched to a hs-cTnI cut-off value of 11 ng/L in male and 5 ng/L in female individuals. Conversely, the sex-specific hs-cTnI cut-off values currently in use (i.e., 34 ng/L in males and 16 ng/L in females) were best matched to a hs-cTnT cut-off value of 49 ng/L in male and 24 ng/L in female individuals. These "harmonised" cut-off values reduced discordant classifications between both assays by 43-68% compared to using cut-off values currently in use. CONCLUSION: Especially in women, reclassification rates were high, when using sex specific versus sex-neutral thresholds. Best matching cut-off values for hs-cTnT and hs-cTnI were markedly different to those currently in use. These "harmonised" cut-off values minimised discordant classifications between both assays.
    [Abstract] [Full Text] [Related] [New Search]