These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Objective sleep in pregnant women: a comparison of actigraphy and polysomnography. Author: Zhu B, Calvo RS, Wu L, Simon L, Shah K, Piano M, Khain U, Izci-Balserak B. Journal: Sleep Health; 2018 Oct; 4(5):390-396. PubMed ID: 30241652. Abstract: OBJECTIVES: To compare different actigraphy scoring settings with polysomnography (PSG) for 1 night of total sleep time (TST), sleep efficiency (SE), wake after sleep onset (WASO), and sleep onset latency (SOL) in healthy pregnant women between 6 and 7 months of gestation. DESIGN: Secondary analysis using data from a case-control study. SETTING: A large university-affiliated hospital in the Midwestern United States. PARTICIPANTS: A total of 78 pregnant women were recruited, among which 38 healthy women with uncomplicated pregnancies were included for this analysis. MEASUREMENTS: Participants had an overnight PSG assessment at a sleep center while simultaneously wearing an actigraph (Minimitter; Philips Respironics, Andover, MA). Sleep parameters from both devices included TST, SE, WASO, and SOL. Four scoring settings were used to obtain these parameters from actigraphy. Bland-Altman tests were used to evaluate the agreement between sleep variables scored independently from actigraphy and PSG. RESULTS: The default scoring setting (10-by-40) yielded significantly different results from the PSG (P < .01). The 10 immobile/mobile minutes for sleep onset/end with an activity threshold of 10 (10-by-10) produced estimations of TST, SE, and WASO closest to those produced by PSG. When this setting was used, the mean differences between PSG- and actigraphy-assessed TST, SE, and WASO were -1.9 minutes, -0.4%, and 7.4 minutes. When the 10 and 15 immobile/mobile minutes for sleep onset/end were used, the difference between PSG- and actigraphy-assessed SOL was approximately 4 to 5 minutes. CONCLUSIONS: Findings from this study do not support the use of default actigraph settings in pregnant women. In contrast, the 10-by-10 scoring setting provided the greatest agreement and least bias in comparison with PSG for sleep measurements. The 10-by-10 scoring setting is recommended to be used in studies consisting of pregnant women.[Abstract] [Full Text] [Related] [New Search]