These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: ε-MnO2-modified graphite electrode as a novel electrochemical sensor for the ultrasensitive detection of the newly FDA approved Hepatitis C antiviral drug ledipasvir. Author: Abdel-Aal FAM, Rageh AH, Said MI, Saleh GA. Journal: Anal Chim Acta; 2018 Dec 14; 1038():29-40. PubMed ID: 30278905. Abstract: A novel, simple and sensitive electrochemical method for the determination of ledipasvir (LED), the newly FDA approved Hepatitis C antiviral drug was developed and validated using ε-MnO2-modified graphite electrode. Two different MnO2 polymorphs (γ- and ε-MnO2 nanoparticles) were synthesized and characterized using X-ray powder diffraction (XRD), Fourier transform infrared (FTIR), energy dispersive X-ray (EDX) and thermogravimetric analysis (TGA). Surface area measurements show that ε-MnO2 NPs have large surface area of 345 m2/g, which is extremely high if compared to that of γ-MnO2 NPs (38 m2/g). In addition, a comprehensive study of the difference in the electrochemical behavior of LED while using pencil graphite electrode (PGE) modified with either γ- or ε-MnO2 NPs is carried out. It was found that surface area and percentage of surface hydroxyls of MnO2 NPs are the key factors governing the sensitivity of the fabricated electrode toward the oxidation of the positively charged LED. Scanning electron microscopy (SEM) was employed to investigate the morphological shape of MnO2 NPs and the surface of the bare and modified electrodes. Moreover, cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were used for the surface analysis of the modified electrodes. Based on the obtained results, ε-MnO2/PGE was applied as a selective and sensitive electrode for determination of LED. Under the optimized experimental conditions, ε-MnO2/PGE provides a linear response over the concentration range of 0.025-3.60 μmol L-1 LED with a low limit of detection, which was found to be 5.10 nmol L-1 (4.50 ng mL-1) for the 1st peak and 9.20 nmol L-1 (8.10 ng mL-1) for the 2nd one. In addition, the oxidation behavior of LED is discussed with a full investigation of the oxidized product using FT-IR and LC/MS. The fabricated sensor exhibits a good precision, selectivity and stability and was applied successfully for the determination of LED in its tablets and real rat plasma samples with a good recovery using a simple extraction technique.[Abstract] [Full Text] [Related] [New Search]