These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Real-Time US-18FDG-PET/CT Image Fusion for Guidance of Thermal Ablation of 18FDG-PET-Positive Liver Metastases: The Added Value of Contrast Enhancement.
    Author: Mauri G, Gennaro N, De Beni S, Ierace T, Goldberg SN, Rodari M, Solbiati LA.
    Journal: Cardiovasc Intervent Radiol; 2019 Jan; 42(1):60-68. PubMed ID: 30288593.
    Abstract:
    PURPOSE: To assess the feasibility of US-18FDG-PET/CT fusion-guided microwave ablation of liver metastases either poorly visible or totally undetectable with US, CEUS and CT, but visualized by PET imaging. MATERIALS AND METHODS: Twenty-three patients with 58 liver metastases underwent microwave ablation guided by image fusion system that combines US with 18FDG-PET/CT images. In 28/58 tumors, 18FDG-PET/CT with contrast medium (PET/CECT) was used. The registration technical feasibility, registration time, rates of correct targeting, technical success at 24 h, final result at 1 year and complications were analyzed and compared between the PET/CT and PET/CECT groups. RESULTS: Registration was successfully performed in all cases with a mean time of 7.8 + 1.7 min (mean + standard deviation), (4.6 + 1.5 min for PET/CECT group versus 10.9 + 1.8 min for PET/CT group, P < 0.01). In total, 46/58 (79.3%) tumors were correctly targeted, while 3/28 (10.7%) and 9/30 (30%) were incorrectly targeted in PET/CT and PET/CECT group, respectively (P < 0.05). Complete ablation was obtained at 24 h in 70.0% of cases (n = 40 tumors), 23/28 (82.1%) in the PET/CECT group and 17/30 (56.7%) in the PET/CT group (P < 0.037). Fourteen tumors underwent local retreatment (11 ablations, 2 with resection and 1 with stereotactic body radiation therapy), while 4 tumors could not be retreated because of distant disease progression and underwent systemic therapy. Finally, 54/58 (93.1%) tumors were completely treated at 1 year. One major complication occurred, a gastrointestinal hemorrhage which required surgical repair. CONCLUSIONS: Percutaneous ablation of 18FDG-PET-positive liver metastases using fusion imaging of real-time US and pre-acquired 18FDG-PET/CT images is feasible, safe and effective. Contrast-enhanced PET/CT improves overall ablation accuracy and shortens procedural duration time.
    [Abstract] [Full Text] [Related] [New Search]