These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Two Ventricles Are Not Better Than One in the Fontan Circulation: Equivalent Late Outcomes. Author: Marathe SP, Zannino D, Shi WY, du Plessis K, Kehr J, Perumal G, Sun J, Gentles TL, Ayer J, Sholler GF, Verrall CE, Alphonso N, Andrews D, d'Udekem Y, Winlaw DS. Journal: Ann Thorac Surg; 2019 Mar; 107(3):852-859. PubMed ID: 30300642. Abstract: BACKGROUND: A subset of patients who underwent Fontan operations has two adequate-sized ventricles, but an anatomic biventricular circulation cannot be achieved because of complex morphology or for technical reasons. This study sought to determine whether these patients with two-ventricle Fontan circulation had superior outcomes compared with those with a single ventricle. METHODS: A binational Fontan Registry of patients (n = 1,377) was analyzed to identify those patients with two adequate ventricles. This cohort was compared with patients with single-ventricle Fontan circulation. The primary end point was a composite end point called "Fontan failure" encompassing death, heart transplantation, Fontan takedown or conversion, protein-losing enteropathy, plastic bronchitis, or New York Heart Association functional class III or IV. RESULTS: A total of 79 Fontan patients with two adequate ventricles (2V) were compared with 1,291 single ventricle (1V) Fontan patients. Median follow-up for the entire cohort was 11.5 years (interquartile range, 5.1 to 18.8 years). There was no difference in unadjusted 15-year freedom from Fontan failure (2V: 81% [95% confidence interval (CI), 69% to 94%] vs 1V: 86% [95% CI, 83% to 88%], p = 0.4). Propensity-score matching for potential confounding factors yielded 75 two-ventricle Fontan patients matched with 604 single-ventricle Fontan patients, in which 15-year freedom from Fontan failure was also not different (2V: 79% [95% CI, 67% to 94%] vs 1V: 87% [95% CI, 84% to 91%], p = 0.3). CONCLUSIONS: The two-ventricle Fontan circulation does not have better outcomes compared with the single-ventricle Fontan circulation. Late outcomes may depend more on other characteristics of the Fontan circulation. This finding is relevant when the Fontan procedure is being considered as an alternative to anatomic repair in patients with complex two-ventricle morphologies.[Abstract] [Full Text] [Related] [New Search]