These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Endotoxin, cat, and house dust mite allergens in electrostatic cloths and bedroom dust.
    Author: Kristono GA, Shorter C, Pierse N, Crane J, Siebers R.
    Journal: J Occup Environ Hyg; 2019 Jan; 16(1):89-96. PubMed ID: 30325697.
    Abstract:
    Environmental exposure to endotoxin, Fel d I (cat) allergen and Der p I (house dust mite) allergen have been associated with asthma symptoms and have been measured in the environment using various sampling methods, including the electrostatic dust collector. The objectives of this study were to investigate whether levels of endotoxin and allergens were detectable in electrostatic dust collectors and to examine the correlation of allergen and endotoxin levels between electrostatic dust collectors and vacuum sampling methods (floor dust and mattress dust). Electrostatic cloths, bedroom floor dust and mattress dust samples from a subset of 60 homes were randomly selected from the Health of Occupants of Mouldy Homes study for allergen and endotoxin analysis. Fel d I and Der p I allergens were analyzed by double monoclonal antibody ELISA and endotoxin by the kinetic Limulus amoebocyte lysate assay. An enhanced ELISA method was used to analyze Der p I in the electrostatic cloths. Endotoxin was detected in all samples, however Fel d I and Der p I were not detected in all electrostatic dust collector samples (detection in 53% and 15% of cloths respectively). No correlations were found between cloth and dust samples for endotoxin or Der p I, but moderate-to-strong correlations were found between all three sampling methods for Fel d I (rs = 0.612-0.715, p < 0.001). Poor correlation was found between floor dust and mattress dust samples for Der p I (rs = 0.256, p = 0.048). Electrostatic dust collectors may provide a way to measure airborne dust and allergen. Given the moderate-to-low correlations with vacuum dust sampling, this may present a unique measurement system which, when collected alongside traditional vacuum dust sampling, could provide additional exposure measures. Further studies are required to correlate endotoxin and allergen levels measured by electrostatic dust collector with air sampling and to explore the relationships between these bioaerosols, environmental factors and asthma.
    [Abstract] [Full Text] [Related] [New Search]