These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Autograft or Allograft? Irradiated or Not? A Contrast Between Autograft and Allograft in Anterior Cruciate Ligament Reconstruction: A Meta-analysis.
    Author: Wang S, Zhang C, Cai Y, Lin X.
    Journal: Arthroscopy; 2018 Dec; 34(12):3258-3265. PubMed ID: 30396800.
    Abstract:
    PURPOSE: To compare the clinical outcomes and adverse events associated with irradiated and nonirradiated allografts in anterior cruciate ligament (ACL) reconstruction. METHODS: PubMed, Web of Science, and EMBASE were searched for randomized controlled trials from January 1990 to March 2018 to compare autograft with allograft in ACL reconstruction. Both objective and subjective outcomes of the function and adverse events were meta-analyzed. Two comparisons were summarized: (1) autograft and nonirradiated allograft and (2) autograft and irradiated allograft. The bias risk was based on the Cochrane Handbook for Systematic Reviews of Interventions. The overall risk ratio or weighted mean difference was calculated using a fixed- or random-effects model. Heterogeneity between studies was evaluated by the Q and the I2 statistics. RESULTS: Eleven trials were included in this review for meta-analysis. A total of 1,172 patients were involved (465 autograft and 461 nonirradiated allograft; 141 autograft and 138 irradiated allograft patients). The average follow-up varied from 2 to >10 years. The mean patient age varied from 22 to 32.8 years. The total failure rate was 2.5%. Our analyses demonstrated better clinical outcomes in autograft than irradiated allograft, which could be observed clearly through the International Knee Documentation Committee score (3.84; 95% confidence interval [CI], 1.93-5.76; P < .0001; I2 = 0%), Lysholm score (2.94; 95% CI, 0.66-5.22; P = .01; I2 = 0%), and Tegner score (0.14; 95% CI, -0.08 to 0.36; P = .22; I2 = 0%) with fewer adverse events 0.20 (95% CI, 0.11-0.39; P < .00001; I2 = 0%). There were no significant differences in autograft and nonirradiated allograft groups (P = .47, P = .27, P = .24, and P = .24, respectively). CONCLUSIONS: Autograft offered greater advantages in functional outcomes and adverse events than irradiated allograft in ACL reconstruction; however, there were no significant differences between autograft and nonirradiated allograft in ACL reconstruction. LEVEL OF EVIDENCE: Level II, meta-analysis of Level I and Level II studies.
    [Abstract] [Full Text] [Related] [New Search]