These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The first-hour-of-the-day sleep EEG reliably identifies interictal epileptiform discharges during long-term video-EEG monitoring.
    Author: Liu X, Issa NP, Rose S, Wu S, Sun T, Towle LV, Warnke PC, Tao JX.
    Journal: Seizure; 2018 Dec; 63():48-51. PubMed ID: 30399461.
    Abstract:
    PURPOSE: To determine the usefulness of the first-hour sleep EEG recording in identifying interictal epileptiform discharges (IEDs) during long-term video-EEG monitoring. METHOD: We retrospectively reviewed 255 consecutive patients who underwent continuous long-term video-EEG monitoring in the adult epilepsy monitoring unit (EMU) at the University of Chicago. The complete video-EEG recording was reviewed, and the occurrence of IEDs was determined for each patient. We compared the occurrence of IEDs observed during the first-hour sleep EEG recordings with the occurrence of IEDs observed during the complete video-EEG recordings. RESULTS: Overall, IEDs were observed in 134 (53%) of 255 patients during the full long-term video-EEG recording with a mean duration of 4 days. IEDs were identified in the first-hour sleep EEG in 125 (49%) of 225 patients. Comparing to reviewing full records, the first hour sleep EEG identified IEDs in 125 (93%) of 134 patients. Of the IED subtypes, the first-hour sleep EEG identified 92 (94%) of 98 patients with temporal lobe IEDs, 11 (92%) of 12 patients with frontal lobe IEDs, 3 (100%) of 3 patients with parietal lobe IEDs, 1(50%) of the 2 patients with occipital lobe IEDs, 16 (94%) of 17 patients with generalized IEDs, and 2 (100%) 2 patients with multi-focal IEDs. CONCLUSIONS: The first-hour sleep EEG reliably predicts the occurrence of IEDs during the long-term video-EEG recording, and therefore can be a time-efficient tool for identifying patients with IEDs during long-term video-EEG recording in the adult epilepsy monitoring unit.
    [Abstract] [Full Text] [Related] [New Search]