These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Electrical stimulation of human fracture healing by means of a slow pulsating, asymmetrical direct current.
    Author: Jorgensen TE.
    Journal: Clin Orthop Relat Res; 1977 May; (124):124-7. PubMed ID: 304401.
    Abstract:
    Twenty-eight tibial fractures were treated with external fixation by means of a Hoffmann apparatus. Through two electrode-screws in the Hoffmann apparatus a slowly pulsating, asymmetrical direct current was applied to the fracture site in each patient. The stimulated patients experienced a 30 per cent acceleration in healing as determined by mechanically stressing the Hoffmann apparatus used for immobilization of the fracture.