These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Virtual Monochromatic Dual-Energy Aortoiliac CT Angiography With Reduced Iodine Dose: A Prospective Randomized Study.
    Author: Patino M, Parakh A, Lo GC, Agrawal M, Kambadakone AR, Oliveira GR, Sahani DV.
    Journal: AJR Am J Roentgenol; 2019 Feb; 212(2):467-474. PubMed ID: 30476460.
    Abstract:
    OBJECTIVE: The purpose of this study was to assess the feasibility of performing abdominopelvic aortoiliac CT angiography (CTA) with 16.0 g of iodine contrast medium acquired with low-energy (40 and 50 keV) virtual monochromatic (VMC) images with rapid-kilovoltage-switching dual-energy CT. SUBJECTS AND METHODS: A total of 52 adults with abdominal aortoiliac aneurysm and prior 120-kVp single-energy CTA (SECTA) with 33 g iodine (standard dose) underwent follow-up dual-energy CTA (DECTA) with a 52% reduced iodine dose. Subjects were randomly assigned to a contrast medium protocol for DECTA examinations: one group (n = 26) received 16.2 g (270 mg I/mL) and the other (n = 26) received 16.0 g (320 mg I/mL). Two readers independently assessed SECTA and VMC DECTA datasets for image quality using a 5-point scale. Aortoiliac intravascular attenuation was measured, and ANOVA was used to compare measurements between VMC DECTA and SECTA images. In a subset of patients with DECTA after endovascular aortic repair, endoleak detection was evaluated on VMC images. Volume CT dose index, dose-length product, and size-specific dose estimate were compared between DECTA and SECTA. RESULTS: All DECTA examinations (n = 52) were rated diagnostic with image quality scores comparable to those of 120-kVp single-energy CTA (40 keV, 4.2-4.4; 50 keV, 4.6-4.8; SECTA, 4.4-4.5). Intravascular attenuation was uniform in all reduced-iodine DECTA examinations and was significantly higher on 40- and 50-keV images than on standard-iodine-dose SECTA images (720 ± 125 HU and 482 ± 82 HU vs 303 ± 65 HU) (p < 0.01). There was no difference in intravascular attenuation between the 16.2-g and the 16.0-g doses (p = 0.82). Sensitivity and specificity for endoleak detection were 78.9-94.7% and 100%. Total dose-length product was lower for DECTA (788 ± 166 mGy · cm) than for SECTA (1114 ± 468 mGy · cm). CONCLUSION: Low-energy VMC DECTA images (40 and 50 keV) acquired with two contrast protocols at approximately 50% reduced iodine dose (16.0 and 16.2 g) provide adequate intravascular attenuation and diagnostic quality for aortoiliac evaluation.
    [Abstract] [Full Text] [Related] [New Search]