These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Mitral Annular Plane Systolic Excursion: A Simple, Reliable Echocardiographic Parameter to Detect Left Ventricular Systolic Dysfunction in Patients Undergoing Off-Pump Coronary Artery Bypass Grafting with Transesophageal Echocardiography.
    Author: Borde DP, Joshi S, Asegaonkar B, Apsingkar P, Pande S, More S, Takalkar U, Deodhar A.
    Journal: J Cardiothorac Vasc Anesth; 2019 May; 33(5):1334-1339. PubMed ID: 30477889.
    Abstract:
    OBJECTIVES: This study's objective was to test the hypothesis that transesophageal echocardiography (TEE)-based mitral annular plane systolic excursion (MAPSE) measurement is useful in perioperative settings to detect left ventricular (LV) systolic dysfunction in patients undergoing off-pump coronary artery bypass grafting (OPCAB). DESIGN: Retrospective observational study. SETTING: Tertiary-care level hospitals. PARTICIPANTS: The study comprised 116 patients undergoing OPCAB to obtain cutoffs of MAPSE to detect LV dysfunction. These cutoffs were validated in another 105 patients from 2 other institutions. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: In 116 patients who had undergone OPCAB during the study period with TEE monitoring, MAPSE was measured post hoc at the lateral and septal mitral (and average) annulus using the software tool M.mode.ify (http://www.ultrasoundoftheweek.com/M.mode.ify). Receiver operating curves were constructed to obtain cutoff values of MAPSE at the lateral and septal (and average) annulus of the mitral valve to predict LV systolic dysfunction, which was defined by an ejection fraction <52% for men and <54% for women as measured using the biplane method of disks. These cutoff values then were validated in another 105 patients. LV systolic dysfunction was present in 43% patients. Youden's index values of 9mm for lateral MPASE (area under the receiver operating curve [AUC] 0.93 [confidence interval {CI} 0.87-0.97]; p < 0.0001); 7mm for septal MAPSE (AUC 0.87 [CI 0.79-0.92]; p < 0.0001); and 9mm for average MAPSE (AUC 0.92 [CI 0.86-0.96]; p < 0.0001) were obtained. These cutoffs were statistically significant in the validation cohort (p < 0.0001) with an AUC of 0.84 (CI 0.75-0.90), sensitivity of 86.2%, specificity of 80.8%, positive predictive value of 84.8%, and negative predictive value of 82.6%. CONCLUSIONS: MAPSE is a simple, rapid, and reliable method to detect LV dysfunction using TEE in patients undergoing OPCAB. Its use as screening tool for LV dysfunction is recommended.
    [Abstract] [Full Text] [Related] [New Search]