These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Microfluidics-based self-assembly of peptide-loaded microgels: Effect of three dimensional (3D) printed micromixer design.
    Author: Borro BC, Bohr A, Bucciarelli S, Boetker JP, Foged C, Rantanen J, Malmsten M.
    Journal: J Colloid Interface Sci; 2019 Mar 07; 538():559-568. PubMed ID: 30551068.
    Abstract:
    In an effort to contribute to research in scalable production systems for polymeric delivery systems loaded with antimicrobial peptides (AMPs), we here investigate effects of hydrodynamic flow conditions on microfluidic particle generation. For this purpose, rapid prototyping using 3D printing was applied to prepare micromixers with three different geometric designs, which were used to prepare Ca2+-cross-linked alginate microgels loaded with the AMP polymyxin B in a continuous process. Based on fluid dynamic simulations, the hydrodynamic flow patterns in the micromixers were designed to be either (i) turbulent with chaotic disruption, (ii) laminar with convective mixing, or (iii) convective with microvortex formation. The physicochemical properties of the microgels prepared with these micromixers were characterized by photon correlation spectroscopy, laser-Doppler micro-electrophoresis, small-angle x-ray scattering, and ellipsometry. The particle size and compactness were found to depend on the micromixer geometry: From such studies, particle size and compactness were found to depend on micromixer geometry, the smallest and most compact particles were obtained by preparation involving microvortex flows, while larger and more diffuse microgels were formed upon laminar mixing. Polymyxin B was found to be localized in the particle interior and to cause particle growth with increasing peptide loading. Ca2+-induced cross-linking of alginate, in turn, results in particle contraction. The peptide encapsulation efficiency was found to be higher than 80% for all investigated micromixer designs; the highest encapsulation efficiency observed for the smallest particles generated by microvortex-mediated self-assembly. Ellipsometry results for surface-immobilized microgels, as well as results on peptide encapsulation, demonstrated electrolyte-induced peptide release. Taken together, these findings demonstrate that rapid prototyping of microfluidics using 3D-printed micromixers offers promises for continuous manufacturing of AMP-loaded microgels. Although the micromixer combining turbulent flow and microvortexes was demonstrated to be the most efficient, all three micromixer designs were found to mediate self-assembly of small microgels displaying efficient peptide encapsulation. This demonstrates the robustness of employing 3D-printed micromixers for microfluidic assembly of AMP-loaded microgels during continuous production.
    [Abstract] [Full Text] [Related] [New Search]