These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Determination of ethylenethiourea residues in tea using precolumn derivatization with ultra-performance liquid chromatography-tandem mass spectrometry]. Author: Zheng X. Journal: Se Pu; 2018 Dec 08; 36(12):1238-1244. PubMed ID: 30574702. Abstract: A method based on precolumn derivatization along with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the determination of ethylenethiourea residues in tea. The sample was extracted using acetonitrile; the extracting solution was purified by matrix-dispersed solid phase extraction and precolumn derivatization using 9-fluorenylmethyl chloroformate (FMOC-CL). The UPLC separation was carried out on an Acquity BEH C18 column (100 mm×2.1 mm, 1.7 μm) and quantified using the isotope internal standard method. The mobile phase was 0.1% (v/v) formic acid and acetonitrile. For tea samples, the detection limit of this method was 1.3 μg/kg and the limit of quantitation was 4.2 μg/kg. The recoveries were in the range 97.7%-107.5% with relative standard deviation (RSD) of 2.1%-10.0% (n=6). The linear correlation coefficient (r) was 0.9993 over the concentration range 1.0-203.4 μg/L. This method showed high sensitivity, good reproducibility, and qualitative and quantitative accuracy, and could be suitable for the detection of ethylenethiourea residues in tea.[Abstract] [Full Text] [Related] [New Search]