These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Construction of a Biosensor Based on a Combination of Cytochrome c, Graphene, and Gold Nanoparticles.
    Author: Guo C, Wang J, Chen X, Li Y, Wu L, Zhang J, Tao CA.
    Journal: Sensors (Basel); 2018 Dec 22; 19(1):. PubMed ID: 30583520.
    Abstract:
    A biosensor based on a combination of cytochrome c (Cyt c), electrochemical reduced graphene oxides (ERGO), and gold nanoparticles (AuNPs) on a glassy carbon electrode (GCE) was fabricated. The proposed biosensor electrode was denoted as GCE/ERGO-Nafion/AuNPs/Cyt c/Nafion, where ERGO-Nafion was deposited by dropping graphene oxides-Nafion mixed droplet first and following electrochemical reduction, AuNPs were directly deposited on the surface of the ERGO-Nafion modified electrode by electrochemical reduction, and other components were deposited by the dropping-dry method. The effect of the deposition amount of AuNPs on direct electrochemistry of Cyt c in the proposed electrode was investigated. The hydrogen peroxide was taken to evaluate the performance of the proposed biosensor. The results showed that the biosensor has great analytical performance, including a high sensitivity, a wide linear range, a low detection limit, and good stability, reproducibility, and reliability.
    [Abstract] [Full Text] [Related] [New Search]