These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Development and validation of HILIC-UHPLC-ELSD methods for determination of sugar alcohols stereoisomers and its application for bioconversion processes of crude glycerin.
    Author: Costa PPKG, Mendes TD, Salum TFC, Pacheco TF, Braga SC, de Almeida JRM, Gonçalves SB, Damaso MCT, Rodrigues CM.
    Journal: J Chromatogr A; 2019 Mar 29; 1589():56-64. PubMed ID: 30621908.
    Abstract:
    The recent increase in the production of crude glycerin through the manufacture of biodiesel has imputed a commercial issue, the excess of this raw material in the market and its constant devaluation, which resulted in the need for new technologies for its use. Crude glycerin can be used in biotechnological processes for the production of high value-added compounds. This study presents novel, simple and fast methods based on ultra-high performance liquid chromatography (UHPLC) using evaporative light scattering detection (ELSD) for simultaneous analysis of ten sugar alcohols with a hydrophilic interaction chromatography (HILIC) column. The selected compounds and their possible stereoisomers have major commercial importance and they can be obtained by biotechnological routes. Under optimized conditions, threitol, erythritol, adonitol, xylitol, arabitol, iditol, sorbitol, mannitol, dulcitol and volemitol can be analyzed simultaneously within 15.0 min. The use of different column temperatures was a key parameter to reach the selectivity during the separation of some stereoisomers. Regression equations revealed a good linear relationship (R > 0.995) over the range from 50.0 to 800.0 ng. Limits of detection (LOD) and quantification (LOQ) ranged from 30.0 to 45.0 ng and 50.0-75.0 ng, respectively. The HILIC-UHPLC-ELSD methods showed good precision with low coefficient of variation (CV%) for the intra- and inter-assays experiments (≤ 5.1%) and high repeatability in terms of retention times for each analyte (≤ 0.5%). The accuracy was confirmed with an average recovery ranging from 92.3 to 107.3%. The developed methods employ an analytical technique more accessible and suitable for routine analyzes and have shown to be suitable for simultaneous analysis of sugar alcohols present in crude bioconverted glycerin samples using different classes of microorganisms.
    [Abstract] [Full Text] [Related] [New Search]