These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Multi-domain features for reducing false positives in automated detection of clustered microcalcifications in digital breast tomosynthesis. Author: Zhang F, Wu S, Zhang C, Chen Q, Yang X, Jiang K, Zheng J. Journal: Med Phys; 2019 Mar; 46(3):1300-1308. PubMed ID: 30661242. Abstract: PURPOSE: In digital breast tomosynthesis (DBT) imaging, a microcalcification (MC) cluster may span across different slices and blurring exists in the out-of-focus slices. We developed a radiomics approach to extract features from focus slice and combine multiple spatial domains to reduce false positives (FPs) in an automated pipeline of detecting MC clusters. METHODS: We performed a retrospective study on a cohort of 290 Chinese women patients with a total of 580 DBT volumes. We developed an automated MC detection pipeline that consists of two stages: an initial detection to identify a set of MC candidates that may include many FPs, followed by a radiomics-based classification model to identify and reduce the FPs. We extract both two-dimensional (2D) and three-dimensional (3D) radiomics features from multiple spatial domains, including a focus slice, projection image, and tomographic volume. A linear discriminant classifier was used coupled with a sequential forward feature selection procedure. The free-response operating characteristics (FROC) curve and partial area under the FROC curve (pAUC) in the FP rate range of 0 to 2 per DBT volume were used to evaluate the model's performance. RESULTS: At a sensitivity of 90%, the FP rate was reduced from 1.3 to 0.2 per DBT volume after applying the multi-domain-based classification on the initial detections. The multi-domain yielded a significantly higher pAUC compared to the initial detection (increase of pAUC = 0.2278, P < 0.0001), focus slice (increase of pAUC = 0.0345, P = 0.0152), project image (increase of pAUC = 0.1043, P < 0.0001), and tomographic volume (increase of pAUC = 0.0791, P = 0.0032). CONCLUSION: The radiomic features extracted from the three domains may provide complementary information and their integration can significantly reduce FPs in automated detection of MCs in DBT volumes on a large Chinese women population.[Abstract] [Full Text] [Related] [New Search]