  • Title: Abnormal ventilation-perfusion scan due to swallowed DTPA aerosol and a paralyzed hemidiaphragm.
    Author: Kolla I, Holt D, Taylor A.
    Journal: Clin Nucl Med; 1988 Nov; 13(11):842-3. PubMed ID: 3069278.
    Abstract:
    A case of ventilation-perfusion mismatch due to swallowed DTPA aerosol and a paralyzed hemidiaphragm is shown as a potential source of error in the evaluation of pulmonary embolus. This case emphasizes the importance of radiograph correlation in the interpretation of ventilation-perfusion images.