These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Integrated PET-MRI for Glioma Surveillance: Perfusion-Metabolism Discordance Rate and Association With Molecular Profiling.
    Author: Seligman L, Kovanlikaya I, Pisapia DJ, Naeger DM, Magge R, Fine HA, Chiang GC.
    Journal: AJR Am J Roentgenol; 2019 Apr; 212(4):883-891. PubMed ID: 30779663.
    Abstract:
    OBJECTIVE: Both 18F-FDG PET and perfusion MRI are commonly used techniques for posttreatment glioma surveillance. Using integrated PET-MRI, we assessed the rate of discordance between simultaneously acquired FDG PET images and dynamic contrast-enhanced (DCE) perfusion MR images and determined whether tumor genetics predicts discordance. MATERIALS AND METHODS: Forty-one consecutive patients with high-grade gliomas (20 with grade IV gliomas and 21 with grade III gliomas) underwent a standardized tumor protocol performed using an integrated 3-T PET-MRI scanner. Quantitative measures of standardized uptake value, plasma volume, and permeability were obtained from segmented whole-tumor volumes of interest and targeted ROIs. ROC curve analysis and the Youden index were used to identify optimal cutoffs for FDG PET and DCE-MRI. Two-by-two contingency tables and percent agreement were used to assess accuracy and concordance. Twenty-six patients (63%) from the cohort underwent next-generation sequencing for tumor genetics. RESULTS: The best-performing FDG PET and DCE-MRI cutoffs achieved sensitivities of 94% and 91%, respectively; specificities of 56% and 89%, respectively; and accuracies of 80% and 83%, respectively. FDG PET and DCE-MRI findings were discordant for 11 patients (27%), with DCE-MRI findings correct for six of these patients (55%). Tumor grade, tumor volume, bevacizumab exposure, and time since radiation predicted discordance between FDG PET and DCE-MRI findings, with an ROC AUC value of 0.78. Isocitrate dehydrogenase gene and receptor tyrosine kinase gene pathway mutations increased the ROC AUC value to 0.83. CONCLUSION: FDG PET and DCE-MRI show comparable accuracy and sensitivity in identifying tumor progression. These modalities were shown to have discordant findings for more than a quarter of the patients assessed. Tumor genetics may contribute to perfusion-metabolism discordance, warranting further investigation.
    [Abstract] [Full Text] [Related] [New Search]