  • Title: Validation of the Nox-T3 Portable Monitor for Diagnosis of Obstructive Sleep Apnea in Patients With Chronic Obstructive Pulmonary Disease.
    Author: Chang Y, Xu L, Han F, Keenan BT, Kneeland-Szanto E, Zhang R, Zhang W, Yu Y, Zuo Y, Pack AI, Kuna ST.
    Journal: J Clin Sleep Med; 2019 Apr 15; 15(4):587-596. PubMed ID: 30952218.
    Abstract:
    STUDY OBJECTIVES: Clinical practice guidelines recommend polysomnography (PSG) for diagnosis of obstructive sleep apnea (OSA) in patients with major comorbidities. We evaluated home sleep apnea testing (HSAT) using a type 3 portable monitor (PM, Nox-T3, Nox Medical, Reykjavik, Iceland) to diagnose OSA in adults with chronic obstructive pulmonary disease (COPD). METHODS: Ninety adults with COPD (89.0% males, mean ± standard deviation age 66.5 ± 7.8 years, body mass index 27.5 ± 5.8 kg/m2, forced expiratory volume in the first second/forced vital capacity [FEV1/ FVC] 53.5 ± 12.4%, FEV1 54.0 ± 18.4% predicted) underwent unattended HSAT followed by an in-laboratory PSG with simultaneous PM recording. RESULTS: Scoring hypopneas with a ≥ 4% oxygen desaturation, the apnea-hypopnea index (AHI) was 16.7 ± 20.6 events/h on HSAT, 20.0 ± 23.3 events/h on in-laboratory PM, and 21.2 ± 26.2 events/h on PSG (P < .0001). Bland-Altman analysis of AHI on HSAT versus PSG showed a mean difference (95% confidence interval) of -5.08 (-7.73, -2.42) events/h (P = .0003) and limits of agreement (± 2 standard deviations) of -30.00 to 19.85 events/h; HSAT underestimated AHI to a greater extent for more severe values (rho = -.529, P < .0001). Using an AHI ≥ 5 events/h to diagnose OSA, HSAT had 95% sensitivity, 78% specificity, 88% positive predictive value, and 89% negative predictive value compared to PSG. Mean oxygen saturation was 93.2 ± 3.7% on PSG, 91.0 ± 3.3% on in-laboratory PM, and 90.8 ± 4.0% on HSAT (P < .0001). Percentage time oxygen saturation ≤ 88% was 17.9 ± 26.4% on HSAT, 17.4 ± 25.5% on in-laboratory PM, and 10.0 ± 21.1% on PSG (P < .0001). CONCLUSIONS: The Nox-T3 PM can be used to diagnose OSA in patients with COPD but, most likely due to differences among pulse oximeters, a greater number of patients with COPD and without OSA qualified for nocturnal oxygen treatment using this PM than PSG.
    [Abstract] [Full Text] [Related] [New Search]