These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Graphene oxide-film-coated splitting ratio-adjustable Mach-Zehnder interferometer for relative humidity sensing. Author: Deng S, Meng H, Wang X, Fan X, Wang Q, Zhou M, Guo X, Wei Z, Wang F, Tan C, Huang X. Journal: Opt Express; 2019 Mar 18; 27(6):9232-9240. PubMed ID: 31052730. Abstract: In this paper, a splitting ratio-adjustable Mach-Zehnder interferometer (MZI) for the measurement of relative humidity (RH) is proposed and experimentally demonstrated. The sensing head contains three sections of single mode fiber (SMF) and two sections of multimode fiber (MMF), in which the two MMFs are spliced among the three SMFs. The MMFs are corroded with hydrofluoric acid and act as mode couplers to split and recombine light owing to the core diameter mismatch with the SMF. A layer of graphene oxide (GO) is coated on the MMFs by dip-coating and natural evaporation. The effective refractive index of the GO will vary when it absorbs the water molecules. As a result, the intensity of the transmission light in the core and cladding of the single mode fiber can be adjusted. Thus, the intensity of the resonant dip will vary when the relative humidity changes. The experimental results show that a humidity sensitivity of 0.263 dB/RH% with a linear correlation coefficient of 99% can be achieved in a relative humidity range of 35% to 85%.[Abstract] [Full Text] [Related] [New Search]