These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Noninvasive Estimation of Aortic Stiffness Through Different Approaches. Author: Salvi P, Scalise F, Rovina M, Moretti F, Salvi L, Grillo A, Gao L, Baldi C, Faini A, Furlanis G, Sorropago A, Millasseau SC, Sorropago G, Carretta R, Avolio AP, Parati G. Journal: Hypertension; 2019 Jul; 74(1):117-129. PubMed ID: 31132954. Abstract: Aortic pulse wave velocity is a worldwide accepted index to evaluate aortic stiffness and can be assessed noninvasively by several methods. This study sought to determine if commonly used noninvasive devices can all accurately estimate aortic pulse wave velocity. Pulse wave velocity was estimated in 102 patients (aged 65±13 years) undergoing diagnostic coronary angiography with 7 noninvasive devices and compared with invasive aortic pulse wave velocity. Devices evaluating carotid-femoral pulse wave velocity (Complior Analyse, PulsePen ET, PulsePen ETT, and SphygmoCor) showed a strong agreement between each other ( r>0.83) and with invasive aortic pulse wave velocity. The mean difference ±SD with the invasive pulse wave velocity was -0.73±2.83 m/s ( r=0.64) for Complior-Analyse: 0.20±2.54 m/s ( r=0.71) for PulsePen-ETT: -0.04±2.33 m/s ( r=0.78) for PulsePen ET; and -0.61±2.57 m/s ( r=0.70) for SphygmoCor. The finger-toe pulse wave velocity, evaluated by pOpmètre, showed only a weak relationship with invasive aortic recording (mean difference ±SD =-0.44±4.44 m/s; r=0.41), and with noninvasive carotid-femoral pulse wave velocity measurements ( r<0.33). Pulse wave velocity estimated through a proprietary algorithm by BPLab (v.5.03 and v.6.02) and Mobil-O-Graph showed a weaker agreement with invasive pulse wave velocity compared with carotid-femoral pulse wave velocity (mean difference ±SD =-0.71±3.55 m/s, r=0.23; 1.04±2.27 m/s, r=0.77; and -1.01±2.54 m/s, r=0.71, respectively), revealing a negative proportional bias at Bland-Altman plot. Aortic pulse wave velocity values provided by BPLab and Mobil-O-Graph were entirely dependent on age-squared and peripheral systolic blood pressure (cumulative r2=0.98 and 0.99, respectively). Thus, among the methods evaluated, only those assessing carotid-femoral pulse wave velocity (Complior Analyse, PulsePen ETT, PulsePen ET, and SphygmoCor) appear to be reliable approaches for estimation of aortic stiffness.[Abstract] [Full Text] [Related] [New Search]