  • Title: Impact of daily soft-tissue image guidance to prostate on pelvic lymph node (PLN) irradiation for prostate patients receiving SBRT.
    Author: Tyagi N, Hipp E, Cloutier M, Charas T, Fontenla S, Mechalakos J, Hunt M, Zelefsky M.
    Journal: J Appl Clin Med Phys; 2019 Jul; 20(7):121-127. PubMed ID: 31206236.
    Abstract:
    PURPOSE: To determine the impact of using fiducial match for daily image-guidance on pelvic lymph node (PLN) coverage for prostate cancer patients receiving stereotactic body radiation therapy (SBRT). METHODS: Thirty patients underwent SBRT treatment to the prostate and PLN from 2014 to 2016. Each patient received either 800cGy × 5 or 500cGy × 5 to the prostate and 500cGy × 5 to the PLN. A 5 mm clinical target volume (CTV)-to-planning target volume (PTV) margin around the PLN was used for planning. Two registrations with planning computed tomography (PCT) for each of the daily cone beam CTs (CBCTs) were performed: a rigid registration to fiducials and to the bony anatomy. The average translational difference between fiducial and bony match as well as percentage of fractions with differences > 5mm were calculated. Changes in bladder and rectal volume as well as center-of-mass (COM) position from simulation parameters, and their correlation with translational difference were also evaluated. The dosimetric impact of the translational differences was calculated by shifting the plan isocenter. RESULTS: The average translational difference between fiducial and bony match was 0.06 ± 0.82, 2.1 ± 4.1, -2.8 ± 4.3, and 5.5 ± 4.2 mm for lateral, vertical, longitudinal, and vector directions. The average change in bladder and rectal volume from simulation was -67.2 ± 163.04 cc (-12 ± 52%) and -1.6 ± 18.75 (-2 ± 30%) cc. The average change in COM of bladder from the simulation position was 0.34 ± 2.49, 4.4 ± 8.1, and -3.9 ± 7.5 mm along the LR, AP, and SI directions. The corresponding COM change for the rectum was 0.17 ± 1.9, 1.34 ± 3.5, and -0.6 ± 5.2 mm. CONCLUSIONS: The 5 mm margin covered ~75% of fractions receiving PLN irradiation with SBRT, daily CBCT and fiducial-guided setup. The dosimetric impact on PLN coverage was significant in 19% of fractions or 25% of patients. A larger translational shift was due to variation in rectal volume and changes in COM position of the bladder and rectum. A consistent bladder positioning and/or rectum filling compared with presimulation volume were essential for adequate coverage of PLN in a hypofractionated treatment regime.
    [Abstract] [Full Text] [Related] [New Search]